14 Technical Data
General data
Dimensions
(width x height x depth)
30 mm x 60 mm x 76 mm
Weight
0.32 kg
Operating temperature range
0
°
C to 50
°
C
Storage temperature range
–20°C to 80°C
Control
Analog
Version
Poppet valve
Permissible medium
Compressed air
Max. particle size
50 μm (oil-free and oiled compressed air)
for pressure range 0 to –1 bar:
5 μm (oil-free compressed air)
Oil content of compressed air
0–1 mg/m
3
The pressure dew point must be at least 15
°
C below the ambient and medium
temperatures and must not exceed 3
°
C.
The oil content of compressed air must remain constant during the life cycle.
O
Use only the approved oils from AVENTICS.
Protection class according
to EN 60529:2000
IP65
(only when assembled and with all plugs
assembled)
Mounting orientation
±
α
= 0 … 90°, ±
β
= 0 … 90°
In dry, grease-free, and dust-free
environments, other mounting orientations are
available on request.
Vibration resistance
If assembled with screws in the through holes
±
10 g
If assembled with mounting kits for mounting
plate or rail
±
1 g
Pneumatics
Flow
0 to 1 bar, 0 to 2 bar, 0 to 6 bar, 0 to 10 bar:
see characteristic curve
–1 to +1 bar: 70 std l/min
0 to –1 bar: 55 std l/min
Output pressure
Supply pressure
Reproducibility
Hysteresis
At 0 to 1 bar
(0 to 14 psi)
Max. 3 bar
(43 psi)
0.01 bar
(0.15 psi)
< 0.01 bar
(< 0.15 psi)
At 0 to 2 bar
(0 to 29 psi)
Max. 7 bar
(101 psi)
0.015 bar
(0.22 psi)
< 0.025 bar
(< 0.36 psi)
At 0 to 6 bar
(0 to 87 psi)
Max. 8 bar
(116 psi)
0.03 bar
(0.43 psi)
< 0.05 bar
<0.73 psi)
At 0 to 10 bar
(0 to 145 psi)
Max. 12 bar
(174 psi)
0.03 bar
(0.43 psi)
< 0.05 bar
(<0.73 psi)
At –1 to +1 bar
(–14 to 14 psi)
Max. 1.5 bar
(22 psi)
0.015 bar
(0.22 psi)
0.025 bar
(0.36 psi)
At 0 to –1 bar
(0 to –14 psi)
–
0.01 bar
(0.15 psi)
< 0.01 bar
(< 0.15 psi)
Electronics
Supply voltage
24 V DC (
±
20%)
Only use a power pack with safe isolation
for the power supply
Permissible harmonic content
5%
Power consumption
max. 300 mA
Input current resistance
(set point)
Supply voltage switched on: 100 W
Supply voltage switched off: > 3 MW
Input voltage resistance
(set point)
Supply voltage switched on: 1.02 M
Ω
Supply voltage switched off: > 3 MW
Current output (actual value),
external working resistance
< 500
Ω
Voltage output (actual value),
external working resistance
> 1 k
Ω
9
8
15 Appendix
Accessories
Dimensioned drawing
See
Standards and directives complied with
DIN EN ISO 4414
“Pneumatic fluid power – General rules and safety
requirements for systems and their components”
DIN EN 61010-1
“Safety requirements for electrical equipment for
measurement, control, and laboratory use – part 1:
general requirements”
DIN EN 61000-6-2
“Electromagnetic compatibility”
(interference immunity in industrial areas)
DIN EN 61000-6-4
“Electromagnetic compatibility”
(interference emission in industrial areas)
Component
Material number
Angled socket M12, 5-pin, for connection on
XPC
1824484029
Connecting cable, 2.5 m, for ED02 pressure regulator
with integrated M12 socket for connection on XPC
R419800109
Connecting cable, 5 m, for ED02 pressure regulator
with integrated M12 socket for connection on
XPC
R419800110
Kit for stacking assembly of 2 units
R414002579
Kit for stacking assembly of 3 units
R414002580
Kit for stacking assembly of 4 units
R414002581
Mounting kit for mounting plate
R414002582
Rail mounting kit TH35-7.5
R414002583
9
AVENTICS
| ED02 | R414002573–BAL–001–AF | English