Description of the front elements and signals  
 

 
Description of operation 

 
The AF979R-DB keypad allows the following functions: 
 

TOTAL 

CONNECTION 

Enter the 5 figure code, warning lights A-B-C light-up, press the RED button 

PARTIAL 

CONNECTION 

Enter the 5 figure code, warning lights A-B-C light-up, press buttons A-B-C of the zones 
required to be excluded, the respective LED goes off, press the RED button 

DISCONNECTION 

Enter the 5 figure code, warning lights A-B-C light-up, press the GREEN button 

 
Erroneous  entry  can  be  cancelled  by  pressing  ESC.  After  8  erroneous  connection  and/or  disconnection 
attempts the keypad is blocked for 30 seconds and all LEDs blink. 
 

 

After each total connection operation, transmission to the control unit and the confirmation response are 
displayed; the keypad emits 3 Beeps and all LEDs of the connected zone remain ON for 30 seconds.  

 

After each partial connection operation, transmission to the control unit and the confirmation response 
are  displayed;  the  keypad  emits  a  long  Beep  and  all  LEDs  of  the  connected  zone  remain  ON  for  30 
seconds.  

 

After each disconnection operation, transmission to the control unit and the confirmation response are 
displayed: the keypad emits a Beep and all zone LEDs remain OFF.  

 

BUTTONS 

DSCRIPTION 

1-9 

Numeric buttons for entering codes. 

A-B-C 

Control unit zones buttons for partial connection.

 

F1 

Radio  control.  Programmed  on  R1R  receivers,  it  transmits  to  the  latter  a  step  by  step 
command.  

F2 

Radio control. Suitably programmed on the control unit, it allows actuating alarms, telephone 
actuations  and/or  calls.  Programmed  on  R1R  radio  receivers,  they  transmit  to  the  latter  a 
monostable (timed) command. 

Panic alarm. It sends a panic alarm to the control unit 

ESC 

Escape button. It deletes erroneous code entry 

Queries control unit. If pressed it queries the control  unit; Upon elapse of the transmission 
and  response  awaiting  period,  displayed  by  special  red  LEDs,  the  LEDs  of  the  connected 
zones light up. If none of the LEDs light up, the system is disconnected. 

 

Connection of the control unit 

 

Disconnection of the control unit 

SIGNALS 

DESCRIPTION 

A-B-C

 

They  Indicate  the  three  intrusion  alarm  zones  and  light  up  when  the  respective  zone  is 
connected

 

 

It indicates that the keypad is transmitting radio signals

 

 

It indicates, upon disconnection, the presence of a new event. Check the control unit events 
memory

 

 

It indicates, upon connection, the presence of possible protected doors/windows left open

 

 

It  indicates,  upon  connection  or  disconnection,  that  the  keypad  batteries  are  low  (to  be 
replaced within 7 days)

 

 

It indicates awaiting the confirmation command from the control unit

 