background image

www.avdel-global.com

© Avdel UK Limited  2007

Avdel®, Avdel® SR, Avex®, Avibulb®, Avinox®, Avseal®, Bulbex®, Genesis®, Interlock®, MBC®, MBC®/LC, Monobolt®, Stavex®, T-Lok®, TLR® are
trademarks of Avdel UK Limited.

AUSTRALIA

Acument Australia Pty Ltd.

891 Wellington Road

Rowville, Victoria 3178

Tel: +61 3 9765 6400

Fax: +61 3 9765 6445

Email: [email protected]

CANADA

Avdel Canada, a Development of

Acument Canada Limited.

87 Disco Road

Rexdale

Ontario M9W 1M3

Tel: +1 416 679 0622

Fax: +1 416 679 0678

Email: [email protected]

CHINA

Acument China Ltd.

RM 1708, 17/F., Nanyang Plaza,

57 Hung To Rd., Kwun Tong

Hong Kong

Tel: +852 2950 0631

Fax: +852 2950 0022

Email: [email protected]

FRANCE

Avdel France S.A.S.

33 bis, rue des Ardennes

BP4 

75921 Paris Cedex 19

Tel: +33 (0) 1 4040 8000

Fax: +33 (0) 1 4208 2450

Email: [email protected]

GERMANY

Avdel Deutschland GmbH

Klusriede 24

30851 Langenhagen

Tel: +49 (0) 511 7288 0

Fax: +49 (0) 511 7288 133

Email: [email protected]

ITALY

Avdel Italia S.r.l.

Viale Lombardia 51/53

20047 Brugherio (MI)

Tel: +39 039 289911

Fax: +39 039 2873079

Email: [email protected]

JAPAN

Acument Japan Kabushiki Kaisha

Center Minami SKY,

3-1 Chigasaki-Chuo, Tsuzuki-ku,

Yokohama-city, Kanagawa Prefecture

Japan 224-0032

Tel: +81 45 947 1200

Fax: +81 45 947 1205

Email: [email protected]

SINGAPORE

Acument Asia Pacific (Pte) Ltd.

#05-03/06 Techlink

31 Kaki Bukit Road 3

Singapore, 417818

Tel: +65 6840 7431

Fax: +65 6840 7409

Email: [email protected]

SOUTH KOREA

Acument Korea Ltd.

212-4, Suyang-Ri,

Silchon-Eup, Kwangju-City,

Kyunggi-Do, Korea, 464-874

Tel: +82 31 798 6340

Fax: +82 31 798 6342

Email: [email protected]

SPAIN

Avdel Spain S.A.

C/ Puerto de la Morcuera, 14

Poligono Industrial Prado Overa

Ctra. de Toledo, km 7,8

28919 Leganés (Madrid)

Tel: +34 (0) 91 3416767

Fax: +34 (0) 91 3416740

Email: [email protected]

UNITED KINGDOM

Avdel UK Limited

Pacific House

2 Swiftfields

Watchmead Industrial Estate

Welwyn Garden City

Hertfordshire

AL7 1LY

Tel: +44 (0) 1707 292000

Fax: +44 (0) 1707 292199

Email: [email protected]

USA

Avdel USA LLC

614 NC Highway 200 South

Stanfield,

North Carolina 28163

Tel: +1 704 888-7100

Fax: +1 704 888-0258

Email: [email protected]

Manual No.

Issue

Change Note No.

A

05/370

A2

05/519

A3

06/536

B

07/044

B2

07/103

B3

07/174

B4

08/008

07900-00842

Содержание Genesis nG3

Страница 1: ...Genesis G3 Hydro Pneumatic Power Tool Instruction Manual...

Страница 2: ......

Страница 3: ...sembly of Base Tool General Assembly 26 Parts List 27 Priming Oil Details 28 Hyspin VG 32 Oil Safety Data 28 Priming Kit 28 Priming Procedure 29 Fault Diagnosis Symptom Possible Cause and Remedy 30 Co...

Страница 4: ...m footing or a stable position before operating the tool machine 10 Ensure that vent holes do not become blocked or covered 11 The operating pressure shall not exceed 7 bar 12 Do not operate the tool...

Страница 5: ...15 cuft Stroke Minimum 26 mm 1 02 in Pull Force 5 5 bar 12 9 kN 2900 lbf Cycle Time Approximately 1 2 seconds Noise Level 75 dB A Weight Including nose equipment 2 25 Kg Vibration Less than 2 5 m s2...

Страница 6: ...3 00 BASE TOOL 1 1 2 3 1 NOSE ASSEMBLY NOSE TIP 2 71223 02000 71210 15000 see note 3 2 3 3 The part number of the base tool remains the same whichever nose assembly or nose tip is fitted See the Gener...

Страница 7: ...REGULATOR AND FILTER DRAIN DAILY 3 METRES MAXIMUM Ensure that the correct nose assembly suitable for the fastener is fitted Connect the tool to the air supply Insert the fastener stem into the nose o...

Страница 8: ...rviced at weekly intervals You should hold some stock of all internal components of the nose assembly and nose tips as they will need regular replacement Use Spanner 07900 00849 supplied with tool to...

Страница 9: ...7340 066012 07612 02001 71210 16020 71210 16070 07381 04701 71210 16070 07381 04701 07498 01401 07340 06201 07340 06201 71210 16070 07381 04701 07498 01401 07612 02001 71210 05002 71210 16070 07348 07...

Страница 10: ...1210 16112 71210 16114 71210 16115 71210 16116 71210 16105 71210 16109 71210 16113 71220 16102 71220 16103 71220 16104 71220 16105 71220 16106 71220 16107 71210 16100 71210 16100 71210 16100 71210 161...

Страница 11: ...COMPLETE TOOL PART NUMBER precede with 71223 00 N O S E A S S E M B L Y part n 71210 15200 A B TYPE 2 NOSE TIPS ARE EXTENDED TO ALLOW ACCESS INTO APPLICATIONS WHERE TYPE 1 NOSE TIPS WILL NOT REACH T Y...

Страница 12: ...B NAME 1 4 1 4 1 4 MONOBOLT INTERLOCK STAVEX T Y P E 6 N O S E T I P S ITEM DESCRIPTION PART N 1 NOSE CASING 07340 00306 2 O RING 07003 00067 3 CHUCK COLLET 07612 02003 4 JAWS 07612 02002 5 JAW SPREA...

Страница 13: ...58 Fit the nose assembly onto the extension Loosen Locknut 40 using 16mm AF Spanner Unscrew and remove both Jaw Spreader Housing 41 and Locknut 40 Replace Locknut 40 with Sealed Nut 71213 02200 screw...

Страница 14: ...17 1 17 3 81 0 84 0 84 0 25 0 25 1 9 2 36 2 46 2 03 2 03 2 03 2 03 3 81 3 81 3 81 3 81 7 87 7 87 7 87 7 87 7 87 7 87 7 87 7 87 7 87 6 35 6 35 7 62 7 62 5 08 5 08 5 08 6 6 6 6 8 13 8 13 4 75 6 35 7 92...

Страница 15: ...01 71213 164022 71213 16403 71213 164042 07345 03700 07345 03800 07345 03700 07345 03800 07345 03301 07494 03601 07494 03011 07345 03401 07494 03701 07345 03501 07494 03801 07165 00701 07165 00702 071...

Страница 16: ...t and slide the jaw carrier assembly back and forth a few times to ensure free movement Go to M L Remove Screws 23 4 off and guard 1 On a straight swivel head also remove Screw 21 and Platform 22 M Pu...

Страница 17: ...el Head illustrations on this page Guard 1 refers to illustration on page 16 While nose tips and jaws will vary for each swivel head other components remain constant within each type of head See table...

Страница 18: ...mbly with special attention to the jaws Lubricate with Moly Lithium grease before assembling Check for oil leaks and air leaks in the air supply hose and fittings Grease can be ordered as a single ite...

Страница 19: ...cal form and water insolubility of the product the bioavailability is negligible Handling General ventilation is recommended Avoid skin and eye contact Storage Do not store with oxidizing agents Keep...

Страница 20: ...ee the nose assemblies section pages 9 to 12 or if a swivel head was fitted pages 14 and 15 For a complete service of the tool we advise that you proceed with dismantling of sub assemblies in the orde...

Страница 21: ...remove Seal Retainer 43 Push Lip Seal 8 and Bearing Tape 26 to the rear and out of Head Assembly 58 taking care not to damage the cylinder bore Remove Seal Housing 52 and Lip Seal 2 Assemble in rever...

Страница 22: ...ing Spanner 07900 00672 and Location Spigot 07900 00671 Unscrew Clamp Nut 39 and remove together with Top Plate Assembly 44 together with Tie Rods 56 Transfer Tube Assembly 61 O Rings 14 and Silencer...

Страница 23: ...reverse order to Dismantling Instructions noting the following Seals should be checked for damage and replaced if necessary lubricated with Molykote 55m grease Ensure Rotary Valve 38 is assembled in...

Страница 24: ...e Shut Off 3 into the assembled parts 1 2 4 and 5 Retain parts in place using grease Molykote 55 Place O Ring 4 into the recess of Cover Plate 6 retain in position using grease Molykote 55 Place sprin...

Страница 25: ...25 Notes...

Страница 26: ...51 B B 41 12 40 1 6 43 52 Assy 58 2 8 17 64 Assy 21 46 Assy 33 42 19 15 35 Assy 36 9 91 13 28 11 X 26 A 89 20 104 Assy 25 Assy 50 79 80 65 Assy 53 14 53 34 14 7 98 99 Assy 59 96 4 22 14 23 62 Assy 24...

Страница 27: ...49 50 51 52 53 56 57 58 59 61 62 63 64 65 66 67 71 72 73 74 75 76 77 79 80 89 90 91 96 97 98 99 100 103 104 71210 02019 71213 02010 71210 02022 71210 02024 71221 02007 71223 02027 71213 02028 71210 03...

Страница 28: ...or several minutes Although NOT a primary irritant minor irritation may occur following contact Fire Flash point 232 C Not classified as flammable Suitable extinguishing media CO2 dry powder foam or w...

Страница 29: ...crew orifice CARE SHALL BE TAKEN TO ENSURE THAT THE BLEED HOLE IS NOT DIRECTED TOWARDS THE OPERATOR OR OTHER PERSONNEL Switch air supply OFF at ON OFF Valve Assembly 62 Screw priming pump 07900 00700...

Страница 30: ...ew spring 8 to 12 Incorrect component in nose assembly Identify and replace 9 to 12 Jaws will not release Build up of dirt inside the nose assembly Service nose assembly 8 broken stem of Jaw housing n...

Страница 31: ...conformity with the following standards EN ISO 12100 parts 1 2 BS EN ISO 8662 part 6 BS EN ISO 11202 BS EN ISO 3744 BS EN 982 ISO EN 792 part 13 2000 BS EN 983 following the provisions of the Machine...

Страница 32: ...39 039 289911 Fax 39 039 2873079 Email vendite acument com JAPAN Acument Japan Kabushiki Kaisha Center Minami SKY 3 1 Chigasaki Chuo Tsuzuki ku Yokohama city Kanagawa Prefecture Japan 224 0032 Tel 81...

Отзывы: