ENVIRONMENT
WASTE DISPOSAL: Through authorised contractor to a
licenced site. May be incinerated.
Used product may be sent for reclamation.
SPILLAGE: Prevent entry into drains, sewers and water courses.
Soak up with absorbent material.
HANDLING
Wear eye protection, impervious gloves (e.g. of PVC) and a
plastic apron. Use in well ventilated area.
STORAGE
No special precautions.
PROPERTIES
RESULT
Foaming tendency/stability
ml @ 24°C
Trace/Nil
ml @ 93.5°C
20/Nil
ml @ 24°C after test @ 93.5°C
Trace/Nil
Air release value minutes to
0.2% air content @ 50°C
4
Seal compatibility index
10
Water separation time
in minutes to 40-40-0 @54°C
15
@83°C
15
P R O C E D U R E
I M P O R T A N T
All operations should be carried out on a clean bench, with clean hands in a clean area.
Ensure that the priming pump is free from foreign matter and that the oil is perfectly clean and free from air bubbles.
Care MUST be taken at all times, to ensure that no foreign matter enters the tool, or serious damage may result.
Item
numbers in bold
refer to the general assembly and parts list pages 14 to 17.
■
Clean the exterior of the tool and stand on clean bench.
■
Disconnect the air supply.
■
Fill the priming pump supplied with every complete tool or available in the service kit, with priming oil. Expel any air by applying pressure
to the end of the pump or ‘actuating’ the pump. Spare threaded nipples are available part number 07900-00250.
■
Remove filler screw
41
and seal
40
at the base of the handle and bleed screw
22
and seal
56
on the side of the head.
■
Screw the priming pump into the hole left by screw
41.
■
Actuate the priming pump several times until the air coming out of the bleed screw hole is free of air bubbles.
■
Replace seal
56
and bleed screw
22.
■
Lay the tool horizontally with the priming pump uppermost. Remove the priming pump.
■
Replace seal
40
and filler screw
41
.
■
Reconnect the air supply and check that the stroke of the tool is within specification. If not, repeat priming procedure.
18
Priming is ALWAYS necessary after the tool has been dismantled and prior to operating. It may also be necessary to restore the full
stroke after considerable use, when the stroke may be reduced and fasteners are not fully placed by one operation of the trigger.
O I L D E T A I L S
The recommended oil for priming is Hyspin VG32 available in 0.5l (part number 07992-00002) or one gallon containers (part numbe r
07992-00006). Please find specific table and safety data below.
P
R I M I N G
FIRST AID
SKIN: Wash thoroughly with soap and water as soon as
possible. Casual contact requires no immediate attention.
Short term contact requires no immediate attention.
INGESTION: Seek medical attention immediately.
DO NOT induce vomiting.
EYES: Irrigate immediately with water for several minutes.
Although NOT a primary irritant, minor irritation may occur
following contact.
FIRE
Suitable extinguishing media: CO2, dry powder, foam or
water fog. DO NOT use water jets.
PROPERTIES
RESULT
ISO oil type
HL
ISO viscosity grade
32
Kinematic viscosity
cS @ 40°C
32
@ 100°C
5.3
Relative density
at 20°C
0.875
Viscosity Index
95
Pour point
°C
- 30
Open Flash point
°C
232
Neutralisation value mg KOH/g
1.5
H Y S P I N V G 32 O I L
S A F E T Y D A T A
Содержание 7611