Avdel 73400-02000 Скачать руководство пользователя страница 46

22

F a u l t   D i a g n o s i s

S y m p t o m

P o s s i b l e   C a u s e

R e m e d y

P a g e   R e f

Hydraulic Hoses not connected

Check for correct connections at HydraPac

and Installation Tool

6

Faulty Hydraulic Quick Couplers

Replace Quick Couplers

7

Faulty electrical connections to 

Check electrical connections

Valve Set

Faulty Directional Valve

Replace Valve

8

Faulty Bridge Rectifier

Replace Bridge Rectifier

17

Loose Manifold flange/damaged

Replace 'O' rings/tighten

8

'O' rings

Manifold flange

Loose hydraulic pipe connections

Tighten connections

9

within oil tank

Faulty hydraulic pipe between pump

Replace hydraulic pipe

and valve

Eccentric bearing loose on motor

Replace eccentric bearing

8

drive shaft

Installation Tool does

not eject the Collar

from the Anvil.

Motor does not

start when the

Trigger Switch on

the Installation Tool

is depressed

Incorrect power supply

Main power supply not switched ON

Isolator in switched OFF position

Control Cord is not plugged in correctly

The fuse has blown

The overload on the Contactor has 
‘tripped out’

Damaged wires in the Control Cord

Loose/damaged connections to
Transformer

Damaged Trigger Switch 

The Contactor Coil has burnt out

The Motor has burnt out

Check power supply

Switch power supply ON

Switch Isolator ON

Check the Control Cord is plugged in at both
the HydraPac and the Installation Tool 

Replace fuse

Reset Contactor Switch

Replace Control Cord

Repair connections

Replace Trigger Switch

Replace Contactor Coil

Replace Motor

5

6

17

17

7,8,17

Installation Tool

cycles but does not

complete the

installation in

breaking off  the

Lockbolt Pintail

The Motor is

running but the

Installation Tool

does not cycle

Pull cycle pressure is low

Internal hydraulic leakage

High oil temperature

‘Sleep Mode’ Timer setting is incorrect

Return Cycle Pressure is too low

Check pressure setting. Pressure relief
to open between 56.2 and 56.9 MPa.
(Use the Pressure Test Gauge Set to Check
and reset if necessary).

Check hydraulic fittings and pipes.
Tighten/replace as necessary.

(60

o

C Max) Check for restriction in

hydraulic line - check couplings and
replace if necessary

Recommended minimum settings:

T10 - 10 seconds

T30 - 15 seconds

T40 - 15 seconds

T51 - 25 seconds

Check pressure setting. Idler valve to open
between 20.0 and 21.7 MPa.

9

7-9

6

9

Содержание 73400-02000

Страница 1: ...Manuel d instructions Traduction du manuel original Groupe hydraulique HydraPac HP21 HP41 HP51...

Страница 2: ......

Страница 3: ...t ou la capacit de s acquitter de la t che pour laquelle il a t con u d un groupe hydraulique quelconque ou de ces pi ces non fabriqu es et ou non fournies par lui Les seules garanties applicables ces...

Страница 4: ...inale inf rieure 10 000 psi 69 0 MPa 8 La pression d utilisation ne doit pas d passer 8 000 psi 55 2 MPa 9 Veiller ce que le cordon libre ne s emm le pas dans un objet pos au sol 10 Pour une utilisati...

Страница 5: ...ge pleine charge 15 0 A 5 3 A 3 8 A Pression de service Traction 55 2 MPa 8 000 psi Retour 20 7 MPa 3 000 psi D bit 2 6 l min 3 3 l min 3 3 l min Fluide hydraulique ISO VG 46 OU EQUIVALENT Pompe Radia...

Страница 6: ...ils 73412 02000 et 25 secondes pour les outils 73410 02000 l HydraPac passe au mode de veille pour conomiser l lectricit et minimiser l usure des pi ces Le d lai de passage au mode de veille peut tre...

Страница 7: ...carr e situ entre l crou et la bobine ni le joint torique mont derri re la bobine L assemblage de la bobine s effectue en inversant la proc dure de d montage D pose de la pompe D poser les huit crous...

Страница 8: ...tourn s vers les l ments et ce que le symbole T TOP DESSUS soit situ au dessus Visser les huit crous Nyloc 36 au couple de 30 Nm en ordre crois l aide d une cl dynamom trique munie d une douille de 17...

Страница 9: ...de cuvette de ressort gauche la plus basse des deux cuvettes pour obtenir le r glage indiqu sur l illustration de l ensemble jauge Une fois la pression qui convient atteinte bloquer la vis de r glage...

Страница 10: ...ERS SOLENOIDE 11 8A 8B 8A 8B 31 34 PORTE FUSIBLE NON ILLUSTRE 30 BRIDE DE MOTEUR 16 PLAQUE DE MONTAGE 35 CAPOT DE MOTEUR DE VENTILATEUR 36 CAPOT DE RESERVOIR TUYAU HYDRAULIQUE EN ACIER CADRE COMPLET C...

Страница 11: ...RECTIONNELLE VALVE MIXTE TEMOIN DE NIVEAU DE FLUIDE COUDE BRIDE DE COLLECTEUR ELEMENTS DE POMPE ELEMENTS DE POMPE VALVE DE PURGE RENIFLARD DE BOUCHON DE REMPLISSAGE DE FLUIDE PARAFOUDRE SECTIONNEUR TR...

Страница 12: ...15 14 21 20 13 VERS SOLENOIDE 11A 11B 8 8 31 34 PORTE FUSIBLE NON ILLUSTRE 30 CAPOT DE MOTEUR DE VENTILATEUR 36 CAPOT DE RESERVOIR TUYAU HYDRAULIQUE EN ACIER CADRE COMPLET CHASSIS CAPOT DE RESERVOIR...

Страница 13: ...VALVE DIRECTIONNELLE VALVE MIXTE TEMOIN DE NIVEAU DE FLUIDE COUDE BRIDE DE COLLECTEUR ELEMENTS DE POMPE VALVE DE PURGE RENIFLARD DE BOUCHON DE REMPLISSAGE DE FLUIDE PARAFOUDRE PARAFOUDRE SECTIONNEUR T...

Страница 14: ...17 9 VIS x 4 2A B 1 35 33 VERS BOITIER 15 14 21 20 13 11A 11B 8 8 31 34 PORTE FUSIBLE NON ILLUSTRE 30 CAPOT DE MOTEUR DE VENTILATEUR 36 CAPOT DE RESERVOIR TUYAU HYDRAULIQUE EN ACIER CADRE COMPLET CHA...

Страница 15: ...RD RAPIDE HYDRAULIQUE MALE FEMELLE VALVE DIRECTIONNELLE VALVE MIXTE TEMOIN DE NIVEAU DE FLUIDE COUDE BRIDE DE COLLECTEUR ELEMENTS DE POMPE VALVE DE PURGE RENIFLARD DE BOUCHON DE REMPLISSAGE DE FLUIDE...

Страница 16: ...TE DE PIECES JEU DE VALVES 3A C165 1 3B C166 1 4 CO27 1 102 CS26 4 103 CS12 8 104 CS34 2 105 XN014 2 106 CO41 2 107 CO42 2 108 CO40 2 109 CO44 2 111 R210 2 112 MS01 1 113 R012 4 ENSEMBLE VALVE DIRECTI...

Страница 17: ...de 7 mm Si de grosses op rations de maintenance doivent tre effectu es sur le moteur 16 la plaque d adaptateur du bo tier peut tre d pos e en desserrant et d posant les quatre vis servant la fixer sur...

Страница 18: ...T BR R 1 220 230 v 50 hz 1 14 3 4 14 5 8 6 3 1 13 I 7 T O L LEGENDE I C T O L M1 T F T R 1 R 2 BR F S 1 Sol SECTIONNEUR DE NEUTRALISATION CONTACTEUR SURCHARGE THERMIQUE MOTEUR MONOPHASE TRANSFORMATEU...

Страница 19: ...525v 50 hz 3 14 3 4 14 5 8 6 3 1 13 I L 1 L 1 L 2 E E S 1 S 2 LEGENDE I C T O L M3 T F T R 1 R 2 BR F S 1 S 2 Sol SECTIONNEUR DE NEUTRALISATION CONTACTEUR SURCHARGE THERMIQUE MOTEUR TRIPHASE TRANSFORM...

Страница 20: ...0 hz 3 14 3 4 14 5 8 6 3 1 13 I L 1 L 1 L 2 E E S 1 S 1 LEGENDE I C T O L M3 T F T R 1 R 2 BR F S 1 S 2 Sol SECTIONNEUR DE NEUTRALISATION CONTACTEUR SURCHARGE THERMIQUE MOTEUR TRIPHASE TRANSFORMATEUR...

Страница 21: ...si le patient est conscient lui faire boire de l eau ou du lait Ne pas le faire vomir moins d avoir t conseill par un personnel m dical Emmener le patient au centre m dical le plus proche YEUX Rincer...

Страница 22: ...de traction trop faible Fuite interne de fluide hydraulique Fluide trop chaud R glage du temporisateur de Mode de veille incorrect Pression de cycle de retour trop faible V rifier l alimentation en l...

Страница 23: ...trial Estate Welwyn Garden City Herts AL7 1LY d clarons sous notre seule responsabilit que le produit Model HP21 HP41 HP51 N de s rie faisant l objet de la pr sente d claration est conforme aux normes...

Страница 24: ...ina infastech com CORR DU SUD Infastech Korea Ltd 212 4 Suyang Ri Silchon Eup Kwangju City Kyunggi Do Korea 464 874 Tel 82 31 798 6340 Fax 82 31 798 6342 info infastech co kr ESPAGNE Avdel Spain S A C...

Страница 25: ...HydraPac Hydraulic Power Unit HP21 HP41 HP51 Instruction Manual Original Instruction...

Страница 26: ......

Страница 27: ...to such unit or part s thereof are those made by the manufacturer thereof and seller agrees to cooperate with buyer in enforcing such warranties when such action is necessary Seller agrees to repair o...

Страница 28: ...ot fit flexible hoses rated at less than 10 000 psi 69 MPa 8 The operating pressure shall not exceed 8 000 psi 55 2 MPa 9 Take care to avoid entanglement of the trailing cable with any object on the f...

Страница 29: ...Hz 50 Hz Full Load Amps 15 0 A 5 3 A 3 8 A Working Pressure Pull 55 2 MPa 8 000 psi Return 20 7 MPa 3 000 psi Delivery Volumes 2 6 l min 3 3 l min 3 3 l min Hydraulic Fluid ISO VG 46 OR EQUIVALENT Pu...

Страница 30: ...iod normally set at 10 seconds for T10 Tools 15 seconds for T30 and T40 Tools and 25 seconds for T51 Tools the HydraPac will enter its Sleep Mode thereby conserving electricity and wear and tear on th...

Страница 31: ...re should be taken not to lose the square section rubber cushion between the nut and the coil and the O ring behind the coil Assembly of the coil is simply the reverse to the stripping procedure above...

Страница 32: ...nd that the symbol T is located on top Tighten the eight Nyloc Nuts 36 to 30 Nm in an opposing sequence using a 17 mm socket and torque wrench Assembling the Combination Valve 4 Replace the two Plunge...

Страница 33: ...he pressure when the release valve opens Adjust the screw on the left hand side Spring Dome the lower of the two domes to obtain the setting given on the Gauge Set illustration Once the correct pressu...

Страница 34: ...URE ASSEMBLY 32 18 29 29 28 27 26 25 24 23 22 16 19 17 9 SCREW 4 OFF 2A B 1 FRAME COMPLETE CHASSIS OIL TANK LID AND GASKET OUTER FRAME AND HANDLE 35 33 36 TO ENCLOSURE 15 MOTOR FLANGE 16 MOUNTING PLAT...

Страница 35: ...ARRESTOR 1 12 CO30 ISOLATOR 1 13 C081 TRANSFORMER 220V 1 14 CO35 ECCENTRIC SHAFT BEARING 1 15 CO34 STUD 8 16 CO22 ELECTRIC MOTOR FAN MOTOR COVER MOTOR FLANGE 1 17 CO89 MOUNTING PLATE 1 19 CO93 TRAILI...

Страница 36: ...6 19 17 9 SCREW 4 OFF 2A B 1 FRAME COMPLETE CHASSIS OIL TANK LID AND GASKET OUTER FRAME AND HANDLE 35 33 TO ENCLOSURE 15 14 21 20 13 TO SOLENOID 11A 11B 8 8 31 34 FUSE HOLDER NOT SHOWN 30 29 MOTOR FLA...

Страница 37: ...SURGE ARRESTOR 1 12 CO30 ISOLATOR 1 13 C082 TRANSFORMER 1 14 CO35 ECCENTRIC SHAFT BEARING 1 15 CO34 STUD 8 16 CO23 ELECTRIC MOTOR FAN MOTOR COVER MOTOR FLANGE 1 17 CO89 MOUNTING PLATE 1 19 CO94 TRAILI...

Страница 38: ...OSURE ASSEMBLY 32 18 29 28 27 26 25 24 23 22 16 19 17 9 SCREW 4 OFF 2A B 1 FRAME COMPLETE CHASSIS OIL TANK LID AND GASKET OUTER FRAME AND HANDLE 35 33 36 TO ENCLOSURE MOUNTING PLATE 15 35 14 21 20 13...

Страница 39: ...URGE ARRESTOR 1 12 CO30 ISOLATOR 1 13 C150 TRANSFORMER 1 14 CO35 ECCENTRIC SHAFT BEARING1 1 15 CO34 STUD 8 16 CO24 ELECTRIC MOTOR FAN MOTOR COVER MOTOR FLANGE 1 17 CO89 MOUNTING PLATE 1 18 C104 GLAND...

Страница 40: ...CRIPTION QTY VALVE SET PARTS LIST 102 CS26 SOCKET HEAD CAP SCREW 4 103 CS12 SOCKET HEAD CAP SCREW 8 104 CS34 SOCKET HEAD CAP SCREW 2 105 XN014 HEXAN NUT 2 106 CO41 SPRING DOME 2 107 CO42 BEARING PAD 2...

Страница 41: ...ier 27 can now be removed and replaced using a flat screwdriver and a 7 mm spanner If it becomes necessary to effect major maintenance on the Motor 16 the Mounting Plate 17 can be removed by loosening...

Страница 42: ...3 T 3 I C F TF T BR R 1 220 230 v 50 hz 1 14 3 4 14 5 8 6 3 1 13 I 7 T O L LEGEND I LOCK OUT ISOLATOR C CONTACTOR T O L THERMAL OVERLOAD M1 SINGLE PHASE MOTOR T F TRANSFORMER T TRIGGER SWITCH R 1 REL...

Страница 43: ...1 400 415v or 525v 50 hz 3 14 3 4 14 5 8 6 3 1 13 I L 1 L 1 L 2 E E S 1 S 2 LEGEND I LOCK OUT ISOLATOR C CONTACTOR T O L THERMAL OVERLOAD M3 THREE PHASE MOTOR T F TRANSFORMER T TRIGGER SWITCH R 1 RELA...

Страница 44: ...BR R 1 525v 50 hz 3 14 3 4 14 5 8 6 3 1 13 I L 1 L 1 L 2 E E S 1 S 1 LEGEND I LOCK OUT ISOLATOR C CONTACTOR T O L THERMAL OVERLOAD M3 THREE PHASE MOTOR T F TRANSFORMER T TRIGGER SWITCH R 1 RELAY R 2...

Страница 45: ...ter Launder contaminated clothing ORAL If swallowed and person is conscious give water or milk Do not induce vomiting unless on advice of medical personnel Take person to nearest medical centre EYES F...

Страница 46: ...wires in the Control Cord Loose damaged connections to Transformer Damaged Trigger Switch The Contactor Coil has burnt out The Motor has burnt out Check power supply Switch power supply ON Switch Iso...

Страница 47: ...of Conformity We Avdel UK Limited Watchmead Industrial Estate Welwyn Garden City Herts AL7 1LY declare under our sole responsibility that the product Model HP21 HP41 HP51 Serial No to which this decla...

Страница 48: ...GmbH Klusriede 24 30851 Langenhagen Tel 49 0 511 7288 0 Fax 49 0 511 7288 133 AvdelDeutschland infastech com INDIA Infastech Fastening Technologies India Private Limited Plot No OZ 14 Hi Tech SEZ SIPC...

Отзывы: