![Avdel 07200 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/avdel/07200/07200_manual_3028416017.webp)
18
Fault Diagnosis
S Y M P T O M
P O S S I B L E C A U S E
R E M E D Y
PA G E R E F
Short stroke or
Offset adaptor setting incorrect
Reset adaptor
14-15
incomplete return
Air leak
Tighten joints or replace components
Worn cam assembly
Replace
Worn roller shafts
Replace
Tool fails to grip
Worn or dirty jaws
Clean or renew as necessary
11
Lockbolt
Broken jaws in nose assembly
Replace
11
Incorrect nose assembly fitted
Change to correct nose assembly
10-11
Tool fails to break
Insufficient air pressure
Adjust air pressure
7
Lockbolt
Incorrect length of bolt
Change to correct length bolt
Tool exhaust silencer dirty
Clean silencer
Tool fails to swage
Offset adaptor setting incorrect
Reset adaptor
14-15
collar
Insufficient air pressure
Adjust air pressure
7
Worn anvils
Replace
11
Swaging anvil cracked
Replace
Incorrect length of bolt
Change to correct length bolt
Tool slows and fails
Insufficient air pressure
Check air supply
7
to actuate
Exhaust silencer dirty
Clean silencer
Other symptoms or failures should be reported to your local Avdel authorised distributor or repair centre.