![AVC Technology CP507 Скачать руководство пользователя страница 53](http://html1.mh-extra.com/html/avc-technology/cp507/cp507_owners-manual_3028388053.webp)
APPENDIX #2
APPENDIX #2
APPENDIX #2
APPENDIX #2
–
–
PIN CONFIGURATION
PIN CONFIGURATION
PIN 1.
GND
GND
GROUND
PIN 2. ~ PIN 9.
ALARM INPUT
ALARM INPUT
To connect wire from ALARM INPUT ( PIN 2 -- 9 ) to GND ( PIN
1 ) connector, DMR will start recording and buzzer will be on.
When Menu/ Camera/ Alarm is set up to
“
Low
”
: When alarm
input signal is
“
Low
”
, the unit starts to record and buzzer.
When Menu/ Camera/ Alarm is set up to
“
High
”
: When alarm
input signal is
“
High
”
, the unit starts to record and buzzer.
PIN 10.
PIN OFF
PIN OFF
PIN 11.
RS232
RS232
-
-
TX
TX
DMR can be controlled remotely by an external device or control
system, such as a control keyboard, using RS-232 serial
communications signals.
PIN 12.
RS485
RS485
-
-
A
A
DMR can be controlled remotely by an external device or control
system, such as a control keyboard, using RS485 serial
communications signals.
PIN 13.
EXTERNAL ALARM NO
EXTERNAL ALARM NO
Under normal operation COM disconnect with NO. But when
Alarm triggered, COM connect with NO.
PIN 14.
PIN OFF
PIN OFF
PIN 15. ~ PIN 22.
ALARM INPUT
ALARM INPUT
To connect wire from ALARM INPUT ( PIN 15 -- 22 ) to GND
( PIN 1 ) connector, DMR will start recording and buzzer will be
on.
When Menu/ Camera/ Alarm is set up to
“
Low
”
: When alarm
input signal is
“
Low
”
, the unit starts to record and buzzer.
When Menu/ Camera/ Alarm is set up to
“
High
”
: When alarm
input signal is
“
High
”
, the unit starts to record and buzzer.
PIN 23.
RS232
RS232
-
-
RX
RX
DMR can be controlled remotely by an external device or control
system, such as a control keyboard, using RS-232 serial
communications signals.
PIN 24.
RS485
RS485
-
-
B
B
DMR can be controlled remotely by an external device or control
system, such as a control keyboard, using RS485 serial
communications signals.
PIN 25.
EXTERNAL ALARM COM
EXTERNAL ALARM COM
Under normal operation COM disconnect with NO. But when
alarm triggered, COM connect with NO.