Connecting to AC power

To connect AC power to the switch, you need an appropriate AC power cord as described in the
following table, also see the following table for plug specifications.

Table 5: International power cord specifications

Country and Plug Specification

Specifications

Typical Plug

Continental Europe:

• CEE7 standard VII male plug

• Harmonized cord (HAR marking on the outside of the cord

jacket to comply with the CENELEC Harmonized
Document HD-21)

• 220 or 230VAC

• 50 Hz

• Single phase

United States of America, Canada, and Japan:

• NEMA5-15P male plug

• UL-recognized (UL stamped on cord jacket)

• CSA-certified (CSA label secured to the cord)

• 100 or 120VAC

• 50–60 Hz

• Single phase

United Kingdom:

• BS1363 male plug with fuse

• Harmonized cord

• 240VAC

• 50 Hz

• Single phase

Australia:

• AS3112-1981 male plug

• 240VAC

• 50 Hz

• Single phase

Danger:

Using power cords with a proper grounding path

Use only power cords that have a grounding path. Without a proper ground, a person who
touches the switch is in danger of receiving an electrical shock. Lack of a grounding path to the
switch can result in excessive emissions.

Connecting to DC power

To connect DC power to the switch, use the short power cable that is provided with the switch.

July 2015

Installation Job Aid for Avaya VSP 4000 4450GSX series     

10

Содержание VSP 4000GSX Series

Страница 1: ...or or reseller Notices Notice paragraphs alert you about issues that require your attention The following paragraphs describe the types of notices used in this guide Note Notes provide tips and useful...

Страница 2: ...dio interference in which case the user may be required to take appropriate measures Caution When mounting this device in a rack do not stack units directly on top of one another in the rack Each unit...

Страница 3: ...upply At least 2 inches 5 08 cm on all sides of the switch unit for ventilation Adequate space at the front and rear of the switch for access to cables If you are installing a single VSP 4000 switch o...

Страница 4: ...le or shelf as illustrated below Allow at least 2 inches 5 1 centimeters on each side for proper ventilation and at least 5 inches 12 7 centimeters at the back for power cord clearance Installing the...

Страница 5: ...ced if necessary The rack is grounded to the same grounding electrode used by the power service in the area The ground path must be permanent and must not exceed 1 Ohm of resistance from the rack to t...

Страница 6: ...ustrated below 3 Slide the transceiver from the module slot 4 If the transceiver does not slide easily from the module slot use a gentle side to side rocking motion while firmly pulling the transceive...

Страница 7: ...hich is lower Table 2 DC power specifications 4450GSX DC Input Current 25A Input Voltage 12VDC Power Consumption Typical 116W Maximum 164 6W Thermal Rating 508 BTU Hr Power supply power specifications...

Страница 8: ...W on 12 ports 835W with one power supply 1835W with two power supplies 17 8W or 32 4W 802 3 at 1 power supply The VSP 4450GSX PWR can support 802 3af 17 8W or 32 4W on each port with one power supply...

Страница 9: ...ceable power supplies 1 If a blanking plate covers the required power supply slot remove the blanking plate before attempting to insert the power supply 2 Insert each power supply into a rear power su...

Страница 10: ...5P male plug UL recognized UL stamped on cord jacket CSA certified CSA label secured to the cord 100 or 120VAC 50 60 Hz Single phase United Kingdom BS1363 male plug with fuse Harmonized cord 240VAC 50...

Страница 11: ...Figure 3 DC power cable Figure 4 DC power cord housing unit with terminals July 2015 Installation Job Aid for Avaya VSP 4000 4450GSX series 11...

Отзывы: