![Avaya VSP 4000 Series Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/avaya/vsp-4000-series/vsp-4000-series_installing_3027997028.webp)
4450GSX-PWR+
Turn on Condition:
1 second maximum after application of AC power
Important:
12 V output rise time, from 10 to 90 per cent, must be the maximum of 50 ms and monotonic under all
defined input and output conditions.
The following table describes the regulatory DC power specifications for the VSP 4450GSX-DC
switch. The regulatory DC power specifications are based on the maximum rated capacity of the
power supplies and are not based on typical power consumption, which is lower.
Table 10: DC power specifications
4450GSX DC
Input Current:
25A
Input Voltage:
12VDC
Power Consumption:
• Typical: 116W
• Maximum: 164.6W
Thermal Rating:
508 BTU/Hr
Related links
Power specifications for the Avaya Virtual Services Platform 4000
Power supply power specifications for the VSP 4450GSX
series switches
The Avaya VSP 4450GSX series switches support two external field replaceable AC and DC power
supplies. One power supply ships with the chassis. You can install a secondary power supply to
provide redundancy, load sharing, and to add Power over Ethernet Plus (PoE+) power budget on
PWR+ models.
AC power supply power specifications
The VSP 4000 4450GSX-PWR+, including the TAA compliant version, supports dual 54V 1000W
Power over Ethernet Plus (PoE+) AC power supplies.
Important:
Ensure that you use only 1000W power supplies (both primary and secondary) on VSP 4000
PWR+ models.
Installing the Avaya VSP 4000 4450GSX series
November 2016
Installing Avaya Virtual Services Platform 4450GSX-PWR+ Switch