Avaya PARTNER ACS R7 Скачать руководство пользователя страница 1

 

Avaya, Inc. Proprietary 

Use Pursuant to Company Instructions 

8/15/2008

 

 

 
 

subject: 

PARTNER® ACS Release 7.0 Attaching a Modem to the 
Administration Serial Port 
Issue 1.0  
COMPAS ID: 104200  

date: 

 

 

April 23, 2004 
 

 

 
 

Engineer’s Notes 

 

1

 

Introduction 

This document explains how to attach a US Robotics modem to the Administration Serial 
Port of a PARTNER ACS R7 processor. This procedure can be used for other modem 
brands, however you must consult your modem’s documentation for the equivalent 
settings. 
 

 

2

 

Tasks Performed 

 

Configure the modem for Administration Serial Port connectivity. 

 

Connect the modem to the Administration Serial Port. 

 

Program PARTNER in order to remove ringing lines from the modem’s extension 
(depending on connectivity method used). 

 

3

 

Equipment Needed 

In order to configure the modem: 

 

PC with an available serial port and terminal emulation software such as 
HyperTerminal. 

 

DB-9 to DB-25 cable (AT modem cable) 

 
To connect the modem to the PARTNER Administration Serial Port: 

 

Standard RJ-45 cable 

 

DB-25 to RJ45 adaptor (355A adaptor or equivalent) 

 

DB-25 to DB-25 Null Modem 