Administering Telephone Options
80 Avaya 1603SW-I SIP Deskphones Administrator Guide
PHY2STAT
1
Secondary Ethernet interface setting
(0=Secondary Ethernet interface off/disabled,
1=auto-negotiate, 2=10Mbps half-duplex, 3=10Mbps
full-duplex, 4=100Mbps half-duplex, 5=100Mbps
full-duplex), and, for post-Release S1.0 use,
6=1000Mbps full-duplex (if supported by the hardware).
Speed and duplex issues are summarized and the best
practice is provided in the
Avaya Application Solutions: IP
Telephony Deployment Guide
, Document Number
555-245-600 Issue 6, January 2008 on page 290. This
document is available from the Avaya support website.
PHY2VLAN
0
VLAN identifier used by frames received on or forwarded
to the secondary Ethernet interface. Set this parameter
only when VLAN separation is “1” (enabled). Value is 1-4
ASCII numeric digits from “0” to “4094.” Null is not a valid
value, nor can the value contain spaces.
PROCPSWD
27238
Text string containing the local (dialpad) procedure
password (Null or 1-7 ASCII digits). If set, password must
be entered immediately after accessing the craft
interface, either during initialization or when Mute is
pressed to access a craft procedure. Intended to facilitate
restricted access to local procedures even when
command sequences are known. Password is viewable,
not hidden.
PROCSTAT
0
Controls access to Craft local (dialpad) administrative
procedures. Values are:
0 = Full access to craft local procedures
1 = restricted access to craft local procedures
RDS_INITIAL_RETRY_
ATTEMPTS
15
Indicates how many times the PPM adaptor should try to
download from PPM before giving up on connecting to
the PPM server. Values are: 1-30.
RDS_INITIAL_RETRY_
TIME
2
Remote Data Source initial retry time in seconds;
indicates the initial delay for a retry to connect to the PPM
server. Valid range is 2-60 (seconds).
RECOVERYREGISTER
WAIT
60
Reactive monitoring interval in seconds for Failover. Valid
values are: 10 - 36000
REGISTERWAIT
900
Number of seconds for next re-registration to SIP server.
The default value for software Release 2.4+ was
originally set to 300 to accommodate UDP, however,
TCP/TLS is the recommended arrangement and is the
most typical configuration; the default was changed from
300 to 900 seconds for software Release 2.5+. UDP
arrangements can be handled by setting the value of the
parameter to a lower value in the settings file. Range in
seconds: 30 to 86400
RTCPCONT
1
Enables/disables the RTCP in parallel to RTP audio
streams. Values are 0=RTCP disabled, 1=RTCP
enabled.
Table 11: 1603SW-I SIP IP Deskphones Customizeable System Parameters (continued)
Parameter Name
Default
Value
Description and Value Range
7 of 10
Содержание one-X 1603SW
Страница 10: ...Introduction 10 Avaya 1603SW I SIP Deskphones Administrator Guide ...
Страница 20: ...Administration Overview and Requirements 20 Avaya 1603SW I SIP Deskphones Administrator Guide ...
Страница 62: ...Server Administration 62 Avaya 1603SW I SIP Deskphones Administrator Guide ...
Страница 72: ...Telephone Software and Binary Files 72 Avaya 1603SW I SIP Deskphones Administrator Guide ...
Страница 118: ...Related Documentation 118 Avaya 1603SW I SIP Deskphones Administrator Guide ...
Страница 124: ...124 Avaya 1603SW I SIP Deskphones Administrator Guide Index ...