Parameter name
Default value
Recommended settings
REGISTERWAIT
900
This parameter represents
number of seconds between
register refreshes. It is
recommended to set the value to
“120” to “180” seconds.
This enables faster recovery
detection of signaling servers.
Related links
Redundancy in generic Open SIP
on page 276
Redundancy in a Broadsoft environment
In a Broadsoft environment, SIP controllers are called application servers. The application servers
are deployed as a cluster containing primary and secondary application servers. A cluster is
represented as a domain with data replicated between the application servers. The phones use
DNS to discover the application servers in the cluster. During DNS lookup operations, DNS returns
the sequence of the servers as primary server followed by secondary server.
For more information on the Broadsoft redundancy deployment, see Broadsoft documentation at
https://xchange.broadsoft.com/
.
Related links
on page 276
Redundancy parameters - Broadsoft
on page 278
Redundancy parameters - Broadsoft
To configure the phone for redundant signaling mode in a Broadsoft environment use
46xxsettings.txt
file to set the following parameters:
Parameter name
Default value
Required settings
SIPREGPROXYPOLICY
simultaneous
This must be set to alternate.
SIP_CONTROLLERS_LIST_2
Null
This parameter should not be set
and left at default.
Open SIP redundancy does not
support IPv6.
3PCC_SERVER_MODE
0
This parameter should be set to
“1”.
Table continues…
SIP server redundancy configuration
April 2020
Installing and Administering Avaya J100 series IP Phones in an Open SIP
environment
278