PARTNER Version Quick Installation Guide
Page 10
- Issue 1b (09 April 2010)
IP Office Essential Edition
1.3 Space Requirements
IP Office control units and external expansion modules are designed to be installed either in a free-standing stack or into a
19" rack system. Rack installation requires a rack mounting kit for the control unit and each expansion module.
If being used without any external expansion modules, the control unit can be wall mounted using a wall mounting kit.
·
Cable Clearance
Clearance must be provided at the front and rear of all modules for cable access. Allow a minimum clearance of
90mm (3.5 inches).
·
Additional Clearance
Care should be taken to ensure that the positioning of the modules does not interrupt air flow and other factors that
may affect
environmental requirements
. This is especially important on control units which have ventilation
slots at the side.
·
Cable Access
Power cords must not be attached to the building surface or run through walls, ceilings, floors and similar openings.
Installation measures must be taken to prevent physical damage to the power supply cord, including proper routing
of the power supply cord and provision of a socket outlet near the fixed equipment or positioning of the equipment
near a socket outlet.
1.3.1 Free Standing
The ventilation slots on the rear and sides should not be covered or blocked.
9
Содержание IP Office Essential Edition PARTNER Version
Страница 1: ... Issue 1b 09 April 2010 PARTNER Version Quick Installation Guide IP Office Essential Edition ...
Страница 4: ......
Страница 6: ......
Страница 24: ...PARTNER Version Quick Installation Guide Page 24 Issue 1b 09 April 2010 IP Office Essential Edition ...
Страница 26: ......
Страница 27: ...PARTNER Version Quick Installation Guide Page 27 Issue 1b 09 April 2010 IP Office Essential Edition ...