• At least 2 inches (5.1 cm) (or one vertical rack width) on all sides of the switch unit for

ventilation.

• Adequate space at the front and rear of the switch for access to cables.

If you are installing a single Ethernet Routing Switch on a table or shelf, ensure the surface can
support at least 7 to 13 pounds (3 to 6 kilograms).

Installation preparation

To prevent damage, handle the switch carefully by using the following guidelines:

• To prevent damage from electrostatic discharge, always wear an antistatic wrist strap

connected to an ESD jack.

• Always place the switch on appropriate antistatic material.

• Support the switch from underneath with two hands. Do not touch components or connector

pins with your hand, or damage can result.

• Do not over tighten screws. Tighten until snug. Do not use a power tool to tighten screws.

For information about technical specifications for the individual switches, see 

Installing Avaya

Ethernet Routing Switch 3600 Series

, NN47213-304.

Installing the switch

The following procedures describe how to install an ERS 3600 Series on a table or shelf, or in an
equipment rack.

Installing an ERS 3600 Series in an equipment rack

Before you begin

Tool requirements

• Phillips screwdriver to attach brackets to the switch and the switch to the rack.

Rack requirements

• Space of 2.8 inches (7.1 centimeters) for each switch in an E1A or 1EC standard 19 inch (48.2

centimeter) equipment rack and T1A 23 inch (58.5 cm) equipment rack.

• Appropriate rack space to accommodate 1U switch height.
• Rack bolted to floor and braced if necessary.
• Rack must be grounded to the same grounding electrode used by the power service in the

area. The ground path must be permanent and must not exceed 1 ohm of resistance from the

rack to the grounding electrode.

Note:

Avaya does not supply the bolts used to secure the switch to the rack. Ensure you obtain the

appropriate bolts to secure the switch to your specific rack before you begin.

Procedure

1. Ensure power is disconnected from the switch.

October 2016

Installation Job Aid for Avaya Ethernet Routing Switch 3600 Series (NN47213–303,

ver 01.01)

4

Содержание ERS 3600 Series

Страница 1: ...vice disruption or damage to products Warning Warning notices provide information about how to avoid personal injury when working with products Voltage Danger High Voltage notices provide information about how to avoid a situation or condition that can cause serious personal injury or death from high voltage or electric shock Danger Danger notices provide information about how to avoid a situation...

Страница 2: ...mounting brackets Mounting brackets are not designed to support multiple units Voltage Use only power cords that have a grounding path Without a proper ground a person who touches the switch is in danger of receiving an electrical shock Lack of a grounding path to the switch can result in excessive emissions Warning Disconnecting the power cord is the only way to turn off power to this device Alwa...

Страница 3: ...dom BS1363 male plug with fuse Harmonized cord 240 VAC 50 Hz Single phase Australia AS3112 1981 male plug 240 VAC 50 Hz Single phase Before you begin Ensure the area where you install and use the switch meets the following environmental requirements Ambient temperature between 32 F and 122 F 0 C and 50 C Relative humidity between 0 and 95 noncondensing No nearby heat sources such as hot air vents ...

Страница 4: ...Series NN47213 304 Installing the switch The following procedures describe how to install an ERS 3600 Series on a table or shelf or in an equipment rack Installing an ERS 3600 Series in an equipment rack Before you begin Tool requirements Phillips screwdriver to attach brackets to the switch and the switch to the rack Rack requirements Space of 2 8 inches 7 1 centimeters for each switch in an E1A ...

Страница 5: ...Figure 1 Rack bracket installation 3 Slide the switch into the rack Insert and tighten the rack mount screws Figure 2 Rack installation 4 Verify that the switch is securely fastened to the rack October 2016 Installation Job Aid for Avaya Ethernet Routing Switch 3600 Series NN47213 303 ver 01 01 5 ...

Страница 6: ...ntry For more information see AC power cord specifications on page 2 Procedure 1 Connect the AC power cord to the back of the switch and then connect the cord to a power outlet Note ERS 3600 Series does not have a power switch When you connect the AC power cord to a suitable AC power outlet the switch powers up immediately October 2016 Installation Job Aid for Avaya Ethernet Routing Switch 3600 Se...

Страница 7: ...ect the cord to a power outlet Danger Using power cords with a proper grounding path Use only power cords that have a grounding path Without a proper ground a person who touches the switch is in danger of receiving an electrical shock Lack of a grounding path to the switch can result in excessive emissions October 2016 Installation Job Aid for Avaya Ethernet Routing Switch 3600 Series NN47213 303 ...

Отзывы: