Table 1: International power cord specifications
Country and plug description
Specifications
Typical plug
Continental Europe
• CEE7 standard VII male plug
• Harmonized cord (HAR marking
on the outside of the cord jacket
to comply with the CENELEC
Harmonized Document HD-21)
220 or 230 VAC
50 Hz
Single phase
U.S./Canada/Japan
• NEMA5-15P male plug
• UL-recognized (UL stamped on
cord jacket)
• CSA-certified (CSA label
secured to the cord)
100 or 120 VAC
50-60 Hz
Single phase
United Kingdom
• BS1363 male plug with fuse
• Harmonized cord
240 VAC
50 Hz
Single phase
Australia
AS3112-1981 male plug
240 VAC
50 Hz
Single phase
Before you begin
Ensure the area where you install and use the switch meets the following environmental
requirements:
• Ambient temperature between 32°F and 122°F (0°C and 50°C).
• Relative humidity between 0% and 95% noncondensing.
• No nearby heat sources such as hot air vents or direct sunlight.
• No nearby sources of severe electromagnetic noise.
• No excessive dust.
• Adequate power source within six feet; one circuit required for each power supply.
October 2016
Installation Job Aid for Avaya Ethernet Routing Switch 3600 Series (NN47213–303,
ver 01.01)
3