AVAYA E1/QSIG
15
display station 3002 Page 2 of 4
STATION
FEATURE OPTIONS
LWC Reception:
none
Auto Select Any Idle Appearance? n
LWC Activation? n Coverage Msg Retrieval? y
LWC Log External Calls? n Auto Answer? none
CDR Privacy? n Data Restriction? n
Redirect Notification? y Idle Appearance Preference? n
Per Button Ring Control? n
Bridged Call Alerting? n Restrict Last Appearance? y
Active Station Ringing: single
H.320 Conversion? n
Per Station CPN – Send Calling Number?
y
MWI Served User Type:
qsig-mwi
Display Client Redirection? n
Select Last Used Appearance? n
Coverage After Forwarding? s
Per Station CPN – Send Calling Number
must be set to “
y
” for the integration to
work properly.
Note:
With QSIG integration the following fields are required for Message
Waiting:
LWC Reception:
none
MWI Served User Type: qsig-mwi
Single Line sets should have field “
Message Waiting Indicator
” set to “
led
” or
“
neon,
” depending on the type of telephone set used. Also, the “
Number of
Rings
” field should be set to a minimum of 4 rings, to allow Personal Assistance
to work properly.
Save these PBX changes.
Please refer to the Consideration section at the end of this document for special
PBX programming considerations.
The above information is provided by AVAYA Inc. as a guide. See disclaimer on page 1