ELECTRICAL  CONNECTION

 

 
 
 

 

If codes permit and a separate ground wire is used, it is recommended that a 
qualified electrician determine that the ground path is adequate.

 

Check with a qualified electrician if you are not sure whether the range is properly

 

grounded.

 

 
Do Not ground to a gas pipe.

 

 

A 120-volt, 60-Hz, AC-only, 15-ampere, fused electrical supply is required. A time-delay 
fuse or circuit breaker is recommended. It is recommended that a separate circuit  
serving only this appliance be provided.

 

 

The outlet must be checked by a qualified electrician to see if it is wired with correct 
polarity.

 

 

This appliance, when installed, must be electrically grounded in accordance with local 
codes.

 

 
 
 

Recommended ground method

 

For your personal safety, this range must be grounded. This range is equipped with a 
3-prong ground plug. To minimize possible shock hazard, the cord must be plugged into 
a mating 3-prong ground-type outlet, grounded in accordance with the National Electrical 
Code ANSI / NFPA 70 latest edition and local codes and ordinances. If a mating outlet  
is not available, it is the personal responsibility and obligation of the customer to have   
a properly polarized and grounded, 3-prong outlet installed by a qualified  electrician.

 

 
 
 

 

 

WARNING 

 

 

Electrical Shock Hazard

 

Plug into a grounded 3-prong 

outlet.

 

Do not remove ground prong. 
Do not use an adapter.

 

Failure to follow these instructions 

can result in death, fire, or electrical 

shock.

 

 

Fig. 27

 

 
 

 

 

 

 

 

 
 

 

 

 

 

Fig. 26

 

WARNING 

VERY IMPORTANT

 

Before any operation of maintenance 
disconnect the appliance from the 
electrical mains supply.

 

Содержание DGR20P3S

Страница 1: ...de ANSI NFPA 70 latest edition and or local codes INSTALLATION IN MANUFACTURED MOBILE HOME The installation must conform with the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3...

Страница 2: ...ot try to light any appliance Donottouchany electricalswitch Do not use any phone in your building lmmediately call your gas supplier from a neighbor s phone Followthegassupplier sinstructions lf you...

Страница 3: ...ess and which are known to the State of California to cause cancer birth defects or other reproductive harm To reduce the risk from substances in fuel or from fuel combustion make sure this appliance...

Страница 4: ...ury or property damage Consult a qualified installer service agent or the gas supplier TOOLS NEEDED FOR INSTALLATION NOT SUPPLIED WITH THE APPLIANCE Screwdriver 2 Wrench T handle wrench Angled hexagon...

Страница 5: ...gas at main supply B Disconnect AC powersupply C Disconnect gas line to the inlet pipe D Carefully remove the range by pulling outward CAUTION Range is heavy use care in handling 12 Electrical Require...

Страница 6: ...aces TO THE LEFT above the 36 914 mm high countertop or there must be a minimum of 11 13 16 300 mm side clearance from the range to such combustible surfaces TO THE RIGHT above the 36 914 mm high coun...

Страница 7: ...7 INSTALLATION PROXIMITY TO SIDE CABINETS GAS AND ELECTRIC CONNECTION...

Страница 8: ...rews provided As shown in the diagram C Secure the backsplash from the bottom using the Philips head screws provided As shown in the diagram HOW TO LEVEL THE RANGE The range is equipped with 4 LEVELLI...

Страница 9: ...gure below only rear right side it has to be fixed on the floor and on the rear wall by four 4 suitable screws not supplied 2 After fixing the anti tip bracket slide range into place Be sure the rear...

Страница 10: ...o 16 for L P gas conversion instructions 1 Manual Shut off Valve The supply line shall be equipped with an approved shutoff valve This valve should be located in the same room as the range and should...

Страница 11: ...the gas supply piping system at test pressure equal to or less than 1 2 PSI 3 5 kPa 3 Flexible Connections If local codes permit CSA design certified flexible metal appliance connector is recommended...

Страница 12: ...must be replaced ALL REPAIR PART REPLACEMENTS AND CONNECTIONS MUST BE DONE BY AN EXPERIENCED LICENSED PROFESSIONAL WARNING Check the right positioning of the gas regulator The arrow on the back of th...

Страница 13: ...the range Gas conversions are the responsibility of the dealer or end user SETTING THE PRESSURE REGULATOR STEP 1 STEP 2 STEP 3 Step 1 Open the regulator cover by turning the cover in a counter clockw...

Страница 14: ...tion of the primary air The following process applies to the following models GRO20P0W GRO24P0W 1 Remove the pan supports 2 Remove the cooktop See the user s guide 3 Remove the screws which secure the...

Страница 15: ...oved Please follow the instructions carefully a Open the door all the way b Lift the left and right hooks on the hinges c Hold the door firmly on each side d Gently close the door and lift upward once...

Страница 16: ...screwing the front screw fig 23 b Gently suspend the burner as shown in figure 24 Take care as not to damage the wire to the ignition electrode as well as the thermocouple c Using a 7 mm box spanner u...

Страница 17: ...Remove the left screw Insert the flat head screwdriver 2 5mm x 75mm Into the screw hole and turn the bypass screw clockwise to adjust the flame DO NOT OVERTIGHTEN 5 Replace the knob 6 Repeat for each...

Страница 18: ...codes Recommended ground method For your personal safety this range must be grounded This range is equipped with a 3 prong ground plug To minimize possible shock hazard the cord must be plugged into...

Страница 19: ...19 ELECTRICAL CONNECTION GR2011CW GR2012CB GR2013CSS GR2414CW GR2415CB GR2416CSS GRO20P0W GRO24P0W DGR20P3S DGR24P3S...

Страница 20: ...Gas range installation manual 07272016 PRINTED IN CHINA...

Отзывы: