background image

- 4 -

User Manual

Please read this manual thoroughly prior to equipment set-up, operation and maintenance.

Inspection

When the equipment is received, all items should be carefully checked against the bill of landing 
to insure all crates and cartons have been received. All units should be inspected for concealed 
damage by uncrating the units immediately. If any damage is found, it should be reported to the 
carrier at once, and a claim should be filed with the carrier. This equipment has been inspected and 
tested in the Avantco Refrigeration. Facility and has been crated in accordance with transportation 
rules and guidelines. Manufacturer is not responsible for freight loss or damage.

Installation

GENERAL

Take care when removing the skid, so that it will not damage the cooler’s finish. Do not tip cabinet to 
install casters or legs. Insure that the casters or legs are screwed all the way into the base.

LOCATION 

The self contained refrigeration system located at the bottom of the cabinet requires free air access 
for proper operation. The back of the cabinet may be positioned against a wall, however, there must 
be a minimum four inch clearance between the sides and a wall. It is necessary to properly level 
cooler to provide adequate drainage and efficient functioning of the unit.

ELECTRICAL 

Check the proposed outlet to be used to insure that the voltage, phase, and current carrying 
capacity of the circuit from the electrical panel correspond to the requirements of the cabinet. Plug 
all standard models into a 110 volts A.C.60 cycle outlet. NEVER use an extension cord to power 
any unit. All wiring between the electrical panel and the unit must be done in accordance with the 
National Electric Code and all state and local codes. Refer to the Serial Tag for all pertinent electrical 
information. 