Avantco FF300 Скачать руководство пользователя страница 20

User Manual

20 www.AvantcoEquipment.com

 

Tank Parts (3 tube shown) 

 

Key  Part Number  Qty  Description 

400037 

Screen, crumb, 3 and 4 tube fryer 

400058 

Screen, crumb, 5 tube fryer 

400036 

Valve, Ball 

C200016 

Tank, 3 tube fryer (excluding flue) 

C200017 

Tank, 4 tube fryer (excluding flue)  

C400056 

Tank, 5 tube fryer (excluding flue) 

400071 

Drain, extension 

400075 

Flue, top, removable, 3 tube fryer 

400076 

Flue, top, removable, 4 tube fryer 

400077 

Flue, top, removable, 5 tube fryer 

400078 

Flue, wrap, top, removable, 3 and 4 tube fryer 

400079 

Flue, wrap, top, removable, 5 tube fryer 

*not shown 

Содержание FF300

Страница 1: ...User Manual www AvantcoEquipment com 1 Floor Fryers Models FF300 FF400 FF518 Please read and keep these instructions Indoor use only 7 16 2013 User Manual...

Страница 2: ...n though not dangerous WARNING FIRE HAZARD FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Keep area around appliances...

Страница 3: ...anual is for Avantco Fryers with 35 pound FF300 55 pound FF400 or 85 pound FF518 capacity frypots The capacity is described on the serial plate that is located inside the front door on the left side T...

Страница 4: ...ural 4 W C 4 30 000 120 000 120 000 39 52 Propane 10 W C 4 30 000 52 FF300 Main Natural 4 W C 3 30 000 90 000 39 Propane 10 W C 3 30 000 90 000 Natural 4 W C 30 000 39 Propane 10 W C 30 000 52 Main 5...

Страница 5: ...examined for damage before and during unloading The freight carrier has assumed responsibility for safe transit and delivery If damaged equipment is received either apparent or concealed a claim must...

Страница 6: ...may void warranty NOTICE When this appliance is installed with casters it must be installed with the casters supplied a connector complying with either ANSI Z21 69 CSA 6 16 and a quick disconnect devi...

Страница 7: ...pack the flue box and flue wrap 2 Slide the flue box over the flue and secure it with the two self tapping screws using a 5 16 socket 3 Slide the flue wrap over the flue 4 Secure it with four self tap...

Страница 8: ...ir supply must also be provided Do NOT obstruct the bottom front of the unit as combustion air enters through this area Be sure to inspect and clean the ventilation system according to the ventilation...

Страница 9: ...when all units are operating simultaneously should not drop below 7 W C for natural gas or 11 W C for propane gas Fluctuations of more than 25 on natural gas or 10 on propane gas will create problems...

Страница 10: ...he knob counterclockwise to the ON position Do not press down on the knob in this step 5 Do NOT turn the thermostat ON until the frypot is filled with oil or solid shortening 6 Once the frypot is fill...

Страница 11: ...only the pilot burner will remain ignited Complete Shutdown Turn knob on the combination gas valve clockwise press down on the knob and continue to turn to the OFF position RELIGHTING 1 Shut off all...

Страница 12: ...es will increase the life of your equipment Climatic conditions e g salt air may result in the need for more thorough and more frequent cleaning in order to keep equipment performing at optimal levels...

Страница 13: ...th Dry thoroughly with a clean cloth Never use vinegar or any corrosive cleaner To remove grease and food splatter or condensed vapors that have baked on the equipment apply cleanser to a damp cloth o...

Страница 14: ...n approved Avantco replacement parts are installed WARNING Adjustments and service work may be performed only by a qualified technician who is experience in and knowledgeable with the operation of com...

Страница 15: ...e tap plug 11 Replace adjustment screw cap CHECKING AND ADJUSTING CALIBRATION OF THERMOSTAT All thermostat controls are carefully calibrated at the factory i e the dial is properly set to control appl...

Страница 16: ...nt cap TROUBLESHOOTING NOTE Vibrations or shock caused by shaking or pounding baskets on top surface or by slamming door may cause Hi Limit Control Switch to open If this condition persists additional...

Страница 17: ...User Manual www AvantcoEquipment com 17 WIRING DIAGRAM...

Страница 18: ...ft side Replacement parts may be ordered either through a Entree Authorized Parts Distributor or a Entree Authorized Service Agency When ordering parts please supply the Model Number Serial Number Par...

Страница 19: ...0044 1 Thermostat Fryer regulating 200 400 4 400042 1 Combination Valve Nat 4 400146 1 Combination valve LP 5 400070 1 Tubing fryer pilot 10 300031 ea Burner Fryer 11 400043 1 Safety thermopile 18 12...

Страница 20: ...l 3 C200016 1 Tank 3 tube fryer excluding flue C200017 1 Tank 4 tube fryer excluding flue C400056 1 Tank 5 tube fryer excluding flue 4 400071 1 Drain extension 5 400075 1 Flue top removable 3 tube fry...

Страница 21: ...User Manual www AvantcoEquipment com 21 User Manual ENTREE FRYERS Leg Parts Caster Parts 400106 400107...

Страница 22: ...hanged altered modified or repaired with parts not authorized or by a nonqualified Avantco Service Technician then Avantco shall not be responsible for warranty claim 6 Adjustments such as calibration...

Страница 23: ...O NEGLIGENCE SHALL NOT EXCEED THE PRICE OF THE EQUIPMENT THAT GIVES RISE TO THE CLAIM 12 If required by Avantco customer shall return to Avantco for examination any failed product or part to confirm t...

Отзывы: