Avantco FF300 Скачать руководство пользователя страница 2

User Manual

2 www.AvantcoEquipment.com

SAFETY PRECAUTIONS

Before installing and operating this equipment, be sure everyone involved in its operation is fully trained and aware of 

precautions. Accidents and problems can be caused by failure to follow fundamental rules and precautions.

The following symbols, found throughout this manual, alert you to potentially dangerous conditions to the operator, 

service personnel, or to the equipment.

DANGER

This symbol warns of immediate hazards that will result in severe injury or death.

WARNING

This symbol refers to a potential hazard or unsafe practice that could result in injury or 

death.

CAUTION

This symbol refers to a potential hazard or unsafe practice that could result in injury, prod-

uct damage or property damage.

NOTICE

This symbol refers to information that needs special attention or must be fully under-

stood, even though not dangerous.

WARNING

FIRE HAZARD

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
Keep area around appliances free and clear of combustibles.
Purchaser of equipment must post in a prominent location, detailed instructions to be followed in the event the 

operator smells gas. Obtain the instructions from the local gas supplier.

WARNING

BURN HAZARD

Contact with hot oil will cause severe burns. Always use caution. Oil at 200°F is more dangerous than boiling water.

WARNING

In the event a gas odor is detected, shut down equipment at the combination gas valve and contact the local gas 

company or gas supplier for service.

NOTICE

Avantco Floor Fryers are intended for commercial use only. Not for household use.
Warranty will be void if service work is performed by other than a qualified technician, or if other than genuine 

Avantco replacement parts are installed.
Be sure this Operator’s Manual and important papers are given to the proper authority to retain for future reference.

Содержание FF300

Страница 1: ...User Manual www AvantcoEquipment com 1 Floor Fryers Models FF300 FF400 FF518 Please read and keep these instructions Indoor use only 7 16 2013 User Manual...

Страница 2: ...n though not dangerous WARNING FIRE HAZARD FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Keep area around appliances...

Страница 3: ...anual is for Avantco Fryers with 35 pound FF300 55 pound FF400 or 85 pound FF518 capacity frypots The capacity is described on the serial plate that is located inside the front door on the left side T...

Страница 4: ...ural 4 W C 4 30 000 120 000 120 000 39 52 Propane 10 W C 4 30 000 52 FF300 Main Natural 4 W C 3 30 000 90 000 39 Propane 10 W C 3 30 000 90 000 Natural 4 W C 30 000 39 Propane 10 W C 30 000 52 Main 5...

Страница 5: ...examined for damage before and during unloading The freight carrier has assumed responsibility for safe transit and delivery If damaged equipment is received either apparent or concealed a claim must...

Страница 6: ...may void warranty NOTICE When this appliance is installed with casters it must be installed with the casters supplied a connector complying with either ANSI Z21 69 CSA 6 16 and a quick disconnect devi...

Страница 7: ...pack the flue box and flue wrap 2 Slide the flue box over the flue and secure it with the two self tapping screws using a 5 16 socket 3 Slide the flue wrap over the flue 4 Secure it with four self tap...

Страница 8: ...ir supply must also be provided Do NOT obstruct the bottom front of the unit as combustion air enters through this area Be sure to inspect and clean the ventilation system according to the ventilation...

Страница 9: ...when all units are operating simultaneously should not drop below 7 W C for natural gas or 11 W C for propane gas Fluctuations of more than 25 on natural gas or 10 on propane gas will create problems...

Страница 10: ...he knob counterclockwise to the ON position Do not press down on the knob in this step 5 Do NOT turn the thermostat ON until the frypot is filled with oil or solid shortening 6 Once the frypot is fill...

Страница 11: ...only the pilot burner will remain ignited Complete Shutdown Turn knob on the combination gas valve clockwise press down on the knob and continue to turn to the OFF position RELIGHTING 1 Shut off all...

Страница 12: ...es will increase the life of your equipment Climatic conditions e g salt air may result in the need for more thorough and more frequent cleaning in order to keep equipment performing at optimal levels...

Страница 13: ...th Dry thoroughly with a clean cloth Never use vinegar or any corrosive cleaner To remove grease and food splatter or condensed vapors that have baked on the equipment apply cleanser to a damp cloth o...

Страница 14: ...n approved Avantco replacement parts are installed WARNING Adjustments and service work may be performed only by a qualified technician who is experience in and knowledgeable with the operation of com...

Страница 15: ...e tap plug 11 Replace adjustment screw cap CHECKING AND ADJUSTING CALIBRATION OF THERMOSTAT All thermostat controls are carefully calibrated at the factory i e the dial is properly set to control appl...

Страница 16: ...nt cap TROUBLESHOOTING NOTE Vibrations or shock caused by shaking or pounding baskets on top surface or by slamming door may cause Hi Limit Control Switch to open If this condition persists additional...

Страница 17: ...User Manual www AvantcoEquipment com 17 WIRING DIAGRAM...

Страница 18: ...ft side Replacement parts may be ordered either through a Entree Authorized Parts Distributor or a Entree Authorized Service Agency When ordering parts please supply the Model Number Serial Number Par...

Страница 19: ...0044 1 Thermostat Fryer regulating 200 400 4 400042 1 Combination Valve Nat 4 400146 1 Combination valve LP 5 400070 1 Tubing fryer pilot 10 300031 ea Burner Fryer 11 400043 1 Safety thermopile 18 12...

Страница 20: ...l 3 C200016 1 Tank 3 tube fryer excluding flue C200017 1 Tank 4 tube fryer excluding flue C400056 1 Tank 5 tube fryer excluding flue 4 400071 1 Drain extension 5 400075 1 Flue top removable 3 tube fry...

Страница 21: ...User Manual www AvantcoEquipment com 21 User Manual ENTREE FRYERS Leg Parts Caster Parts 400106 400107...

Страница 22: ...hanged altered modified or repaired with parts not authorized or by a nonqualified Avantco Service Technician then Avantco shall not be responsible for warranty claim 6 Adjustments such as calibration...

Страница 23: ...O NEGLIGENCE SHALL NOT EXCEED THE PRICE OF THE EQUIPMENT THAT GIVES RISE TO THE CLAIM 12 If required by Avantco customer shall return to Avantco for examination any failed product or part to confirm t...