![Avalue Technology FPC-1736 Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/avalue-technology/fpc-1736/fpc-1736_quick-reference-manual_3024763040.webp)
FPC-1736
40 FPC-1736 Quick Reference Guide
conflict with system resources.
The optional settings: [IO=2F8h; IRQ=3]; [IO=3F8h; IRQ=3,4,5,7,10,11] ; [IO=2F8h;
IRQ=3,4,5,7,10,11] ; [IO=3E8h; IRQ=3,4,5,7,10,11] ; [IO=2E8h; IRQ=3,4,5,7,10,11]
►
Serial Port 3 Configuration
Press [Enter] to make settings for the following items:
Serial Port
Use this item to enable or disable serial port (COM).
The optional settings: [Disabled]; [Enabled].
Press
[Enter]
to make settings for the following sub-items:
Device Settings
Change Settings
Use this item to select an optimal setting for super IO device. Changing setting may
conflict with system resources.
The optional settings: [IO=3E8h; IRQ=11]; [IO=3F8h; IRQ=3,4,5,7,10,11] ; [IO=2F8h;
IRQ=3,4,5,7,10,11] ; [IO=3E8h; IRQ=3,4,5,7,10,11] ; [IO=2E8h; IRQ=3,4,5,7,10,11] ];
[IO=3E0h; IRQ=3,4,5,7,10,11] ]; [IO=2E0h; IRQ=3,4,5,7,10,11]
►
Serial Port 4 Configuration
Press [Enter] to make settings for the following items:
Serial Port
Use this item to enable or disable serial port (COM).
The optional settings: [Disabled]; [Enabled].
Press
[Enter]
to make settings for the following sub-items:
Device Settings
Change Settings
Use this item to select an optimal setting for super IO device. Changing setting may
conflict with system resources.
The optional settings: [IO=2E8h; IRQ=10]; [IO=3F8h; IRQ=3,4,5,7,10,11] ; [IO=2F8h;
IRQ=3,4,5,7,10,11] ; [IO=3E8h; IRQ=3,4,5,7,10,11] ; [IO=2E8h; IRQ=3,4,5,7,10,11] ];
[IO=3E0h; IRQ=3,4,5,7,10,11] ]; [IO=2E0h; IRQ=3,4,5,7,10,11]
WatchDog Reset Timer
Use this item to enable or disable WDT reset function.
The optional settings: [Disabled]; [Enabled].
When set as [Enabled], the following sub-items shall appear:
WatchDog Reset Timer Value
User can select a value in the range of [10] to [255
] seconds when ‘
WatchDog Reset
Timer Unit
’ set as [Sec]; or in the range of [1] to [255] minutes when ‘
WatchDog Reset
Timer Unit
’ set as [Min].
WatchDog Reset Timer Unit
The optional settings are: [Sec.]; [Min.].
Содержание FPC-1736
Страница 11: ...Quick Reference Guide FPC 1736 Quick Reference Guide 11 1 5 System Dimensions Unit mm...
Страница 15: ...Quick Reference Guide FPC 1736 Quick Reference Guide 15 Step 2 Install the expansion module and fasten screw...
Страница 16: ...FPC 1736 16 FPC 1736 Quick Reference Guide 2 3 Motherboard Overviews...
Страница 32: ...FPC 1736 32 FPC 1736 Quick Reference Guide 3 BIOS Setup...