EBM-APL
User’s Manual
52 EBM-APL
User’s Manual
USB Mass Storage Driver Support
Disabled
Enabled
[Default]
Enable/Disable USB Mass Storage Driver
Support.
USB transfer time-out
1 sec
5 sec
10 sec
20 sec
[Default]
The time-out value for Control, Bulk, and
Interrupt transfers.
Device reset time-out
10 sec
20 sec
[Default]
30 sec
40 sec
USB mass storage device Start Unit command
time-out.
Device power-up delay
Auto
[Default]
Manual
Maximum time the device will take before it
properly reports itself to the Host Controller.
‘Auto’ uses default value: for a Root port it is
100ms, for a Hub port the delay is taken form
Hub descriptor.
3.6.2.12 Security Configuration
Item
Options
Description
TXE HMRFPO
Enabled,
Disabled
[Default]
TXE HMRFPO.
TXE EOP Message
Enabled
[Default]
Disabled
Send EOP Message Before Enter OS.