Service Software
7
SERVICE SOFTWARE
The software allows you to control the machine parameters and retrieve user data from the equipment.
To access the machine parameters:
1. Unlock and open the door of the equipment
2. Press the black SET UP button located on the lower section of the main board (#SW2)
The LCD will indicate:
To access the user data:
1. Unlock and open the door of the equipment
2. Press the white COUNTER button located on the lower section of the main board (#SW1)
The LCD will indicate:
Machine Parameters Menu
Café Latté:
- / No
The START button is also used to confirm a
changein a configuration, if it is not pushed
after a change, the modification will not be
kept in memory.
Mokaccino:
+ / Yes
Hot Water:
Move window
Start:
Move character
/ Exit and save
7.1
Configuration:
Open the main door and press the black SETUP ( # SW2) button on the main board. Hit the
strenght
button on the selection membrane and the configuration menu will appear. Scroll through the options
using the hot water button and keep in mind that the café latté button equals no and the Mokaccino
button equals yes. Follow the menu from left to right.
Choose your
language English
You also have the
choice of French
as a language.
Active buzzer
y/n? yes
Option NO will disable the sound signal.
Setup dictionnary
no
This is a list of popular
names for beverages.
Press START to see
the menu. (See next
page for list)
12 oz cup
no
The option YES will let
you have access to the
double infusion function
(For large cup only)
Overflow detection?
yes
You should
leave this
option on YES,
Option NO
can lead to an
error message
in case of an
overflow .
Detailled counter?
yes
If option NO is
selected you
will only see the
general total
screens.
Cntr before
cleaning
00000
This option is a meter that counts the
number of servings before cleaning is
needed
Purchase required
no
Option YES will
force a purchase
to receive change.
Thermostat
000 degree F
This option is a meter for the thermostat
temperature
Setup mode
Press START to exit
Display TOTAL
Press START to exit