![Avalon La Petite-X Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/avalon/la-petite-x/la-petite-x_service-manual_3024294025.webp)
The Petite-X Revision B 03/2010
SERVICE MANUAL AVALON
La Petite-X
Single-Cup Brewer
25
Initial Setup
Heater safety switch
6.3
Levelling the Equipment
For optimal performance of the equipment, it is important to ensure that it is leveled. Avoiding to do so
can create variations in product delivery.
1. Place a level on the top of the machine;
2. Adjust the 4 threaded level glides or legs of the equipment to reach a leveled position.
6.4
Hot Water Tank Preparation
Make sure equipment is unplugged!
6.4.1 Tank Lid Preparation
3. Open the door of the equipment;
4. Remove the back panel or small tank lid;
5. Locate the water tank and remove the twist-tie securing the float of the water tank;
6. Remove the silicone tubing on the heating element;
7. Connect the white wire to the prong on the heating element;
8. Replace the top lid and close door.
* You can easily access to the switches by opening the door on the top of the back panel
Left side view
Water level switch
(float)
Right side view
Heater
safety switch
Water level switch
(float)
Heating element
wire