background image

4

Figure 2. Bus Interface Control Signals.

For product information and a complete list of distributors, please go to our web site:         

www.avagotech.com

Avago, Avago Technologies, and the A logo are trademarks of Avago Technologies, Limited in the United States and other countries.
Data subject to change.  Copyright © 2007 Avago Technologies Limited. All rights reserved.  
5964-3770E - February 7, 2007

D0

3

D1

4

D2

7

D3

8

D4

13

D5

14

D6

17

D7

18

OC

1

G

11

Q0 2

Q1 5

Q2 6

Q3 9

Q4 12

Q5 15

Q6 16

Q7 19

1

2

4

5

1

2

6

Y0

15

Y1

14

Y2

13

Y3

12

Y4

11

Y5

10

Y6

9

Y7

7

A

1

B

2

C

3

G1

6

G2A

4

G2B

5

U2

74HC138

E

AD0

AD1

AD2

AD3

AD4

AD5

AD6

AD7

AS

74HC373

U1

U4A

U6A

74HC20

74HC32

U3C

74HC00

U5

74HC30

U3D

74HC00

A15

A14

A13

A12

A11

A10

A9

A8

9

8

11

12

10

12

13

11

6

5

4

3

8

2

1

U3A

74HC00

U3B

74HC00

1

3

SEL

6

2

4

5

R/W

*

OE

*

RST

*

3

MC68HC11 BUS

NOTE: ALL

*

SIGNALS ARE ACTIVE LOW.

5563-2

Содержание MC68HC11

Страница 1: ...TAB 1004 SEL HI AND OE LO LDAB 1003 LO BYTE IN REG B XGDX REGISTER IX HAS THE 16 BIT VALUE FROM THE HCTL 2020 LDAA 0FF STAA 1004 SEL HI AND OE HI PULB RESTORE REG B FROM STACK PULA RESTORE REG A FROM STACK RTS THIS SUBROUTINE IS USED TO RESET THE HCTL 2020 IN THE PORT INTERFACE RST2020 PSHA LDAA 0EF STAA 1004 RST LO LDAA 0FF STAA 1004 RST HI PULA RTS Port Interface The connections are shown in Fig...

Страница 2: ... PB2 40 PB3 39 PB4 38 PB5 37 PB6 36 PB7 35 PC0 9 PC1 10 PC2 11 PC3 12 PC4 13 PC5 14 PC6 15 PC7 16 PD0 20 PD1 21 PD2 22 PD3 23 PD4 24 PD5 25 MODA 3 E 5 AS 4 R W 6 DO 1 2 SEL 3 OE 4 U D 5 NC 6 RST 7 CHB 8 CHA 9 VSS 10 VDD 20 D1 19 D2 18 D3 17 CNTDCDR 16 CNTCAS 15 D4 14 D5 13 D6 12 D7 11 68HC11E9 U1 HCTL 2020 U2 Vcc NOTE 68HC11E9 IS IN THE SINGLE CHIP MODE REFER TO THE 68HC11E9 REFERENCE MANUAL FOR D...

Страница 3: ...to read and reset follow THIS SUBROUTINE READS A VALUE FROM THE HCTL 2020 THE HIGH BYTE OF DATA IS RE TURNED IN REG IY IN THE CORRECT ORDER OF HIGH AND LOW BYTES THE TWO BYTES ARE MAPPED AT THE MEMORY LOCATIONS AT 0CFFOh AND 0CFF1h RE SPECTIVELY H2020 EQU 0C000 RD2020 LDY H2020 RTS THIS SUBROUTINE IS USED TO RESET THE HCTL 2020 THE RESET SIGNAL IS MAPPED TO MEMORY LOCATION 0CFF2h REST2020 EQU 0CFF...

Страница 4: ... Limited All rights reserved 5964 3770E February 7 2007 D0 3 D1 4 D2 7 D3 8 D4 13 D5 14 D6 17 D7 18 OC 1 G 11 Q0 2 Q1 5 Q2 6 Q3 9 Q4 12 Q5 15 Q6 16 Q7 19 1 2 4 5 1 2 6 Y0 15 Y1 14 Y2 13 Y3 12 Y4 11 Y5 10 Y6 9 Y7 7 A 1 B 2 C 3 G1 6 G2A 4 G2B 5 U2 74HC138 E AD0 AD1 AD2 AD3 AD4 AD5 AD6 AD7 AS 74HC373 U1 U4A U6A 74HC20 74HC32 U3C 74HC00 U5 74HC30 U3D 74HC00 A15 A14 A13 A12 A11 A10 A9 A8 9 8 11 12 10 1...