SC MASTER LITE
SC NET System
•
51
2. Right-click the corresponding control channel and select
Properties
. The Properties Dialog will appear.
Î
Under
Address
enter the new address and confirm with
OK
.
Setting the addresses at the hardware
For an SC Net Module to be able to perform the programmed
functions, the device address listed in the Media Pool under
Devices
must be set in the module. Currently the address
setting is performed via SC Master components. At a later
time, this will also be possible via Wings Platinum.
This is how you set the device addresses at the SC Master
and the SC Net Modules:
1. Connect the SC Master with the SC Net Modules and
switch on the system.
2. In the SC Master menu go to "Options – SC-Net –
Ne-
tAdrs
" and select
NA=1
.
3. In order to establish communication within the SC Net,
switch on the SC Master and off again. When starting up
the SC Master, a message such as "
SC-Baud: 460800
"
must briefly be displayed (the value depends on the baud
rate). After communication has been established, the blue
SC Net LED at the SC Net modules will blink at an interval
of a few seconds. In the event of no communication being
established, refer to page 53 for further information.
4. Return to the menu and select the address you want to
allocate to an SC Net Module, e.g.
EA=2
under "Options –
SC-Net –
ExtAdrs
".
Содержание SC MASTER LITE
Страница 1: ...SC MASTER LITE AV Stumpfl...
Страница 2: ......
Страница 7: ...SC MASTER LITE Contents v Glossary 101 Index 104...
Страница 8: ......
Страница 16: ......
Страница 30: ......
Страница 69: ...SC MASTER LITE The Menu 61 Menu Chart...
Страница 70: ...62 The Menu...
Страница 102: ...94 Technical Appendix SC NET connector 1 CAN GND 2 CAN VDD 5V max 50mA 3 TxD 4 CAN H 5 CAN L 6 RxD 7 N C 8 N C...