SC NET System
Net modules within the network. Usually, the power supply unit
AC-3 can supply up to five SC Net modules. However, there
are also some modules which require a separate power supply
unit.
Address configuration
Device address 1 is always allocated to the master unit. De-
vice addresses 2 to 125 are used for the modules (slaves)
within the network. If address 2 or higher is allocated to an SC
Master unit, it is regarded as a module within the network.
Every SC Net device offers particular functions to be ad-
dressed via subaddresses. After adding SC Net devices under
"
Devices
" in the Wings Platinum Media Pool, they are listed
with their particular functions while Wings Platinum automati-
cally allocates an address, which, however, can be altered at
any time. An SC RELAY 8out, for instance, would be visible as
8 switching contacts with addresses
2/1
to
2/8
, i.e.
2
would be
the device address and
1
to
8
the subaddresses of the individ-
ual relay contacts.
Setting addresses in the Media Pool
If you want to change the address settings in Wings Platinum,
e.g. when different hardware is to be used for controlling,
proceed as follows:
1. Click
on
tab
Devices
in the Media Pool. If the correspond-
ing devices are not displayed, click on the plus sign in
front of the device port.
Содержание SC MASTER LITE
Страница 1: ...SC MASTER LITE AV Stumpfl...
Страница 2: ......
Страница 7: ...SC MASTER LITE Contents v Glossary 101 Index 104...
Страница 8: ......
Страница 16: ......
Страница 30: ......
Страница 69: ...SC MASTER LITE The Menu 61 Menu Chart...
Страница 70: ...62 The Menu...
Страница 102: ...94 Technical Appendix SC NET connector 1 CAN GND 2 CAN VDD 5V max 50mA 3 TxD 4 CAN H 5 CAN L 6 RxD 7 N C 8 N C...