8.2 RS-232 Commands
You can also operate and configure the Switcher via a remote terminal session using
RS-232. Follow the steps as below to log into the Switcher by means of a RS-232
session (the example as below is for Hyper Terminal):
1. Connect the Switcher to your control PC with RS-232 cable.
2. Power on both Switcher and control PC.
3. Open the Hyper Terminal by clicking
Start
│
Programs
│
Accessories
Communications
│
Hyper Terminal
on your control PC.
4. The
New Connection – Hyper Terminal
screen will appear. Input the connection
name and select a representative icon. Then click
OK
.
5. Select the connecting port that you want to use, click
OK
. Default port is
COM1
.
6. Set the Bits per second to
9600
, Data Bits to
8
(Default),
Parity to
None
(Default), Stop
bits to
1
(Default)
and flow control to
None
from the drop-down list, click
OK
.
Please switch the DIP Switcher PIN 1-5, PIN 7 to DOWN (ON) for RS-232
configuration.