Fig.8
1
40
If no impulse signal feedback from the indoor motor 10 second after it was filled with voltage,
the controller will turn off automatically, 30 second later it will restart and impose voltage to
the indoor motor again, if still no impulse signal were detected the controller will hold on,
at the same time the digital tube will show the malfunction code as E4, if you turn off the power,
the malfunction display will disappear.
8-14 definition of louver waving angle
8.Function Exposition
(Fig. 8) ASW-H18A4/E# means the
E series wall mounted type air conditioner
(excluding ):
1. When filled with power, the louver will completely closed, the waving speed is 22 /s;
2. After the unit was turn on, the louver will unwind, and it will swing to the original position
when heating, it will stop at the 5th position
; While cooling it will swing to the
2nd position
.
3. The louver button on the remote control can be setting as free waving and manual waving;
4. Free waving, when heating the waving scope is 50 , from 3 to 5
,
waving angle of
ASW-H18A4/E#
(pic 3)
(pic 3)
(as pic 3) when cooling
the waving scope is 50 , from2 to 4 (as pic 3); the waving speed is 5.5 /s;
5. After the unit was turn on, if the louver was setting as unwave by remote control ,the waving
angle will positioning to a proper height according to different mode, e.g. cooling mode was
showed as 2nd position (pic 3), while heating mode was showed as 5th position (pic 3), after
the fan motor was opened it will resume waving automatically; if the remote control set it as
manual waving the waving angle won t change;
6. After the fan motor stop running the louver will close automatically;
7. When the force button was pressed the unit will run into automatic mode, the louver will
open after the system running, heretofore the louver stop at the norm cooling position.
,
Position 1
Position 2
Position 3
Position 4
Position 6
(louver is all open)
Position 5
heating datum mark
the dead position of the swinging vane
16
0
77
0
50
0
50
0
Cooling datum mark
the dead position of the swinging vane
Содержание ASW-09A4/E Series
Страница 3: ...2 1 Appearance 2 Technical Specification 2 ...
Страница 4: ...OUTDOOR UNIT INDOOR UNIT 2 1 Appearance continue 2 Technical Specification 3 ...
Страница 15: ...4 Wiring Diagram 4 1 ASW H 24B4 E Indoor Unit 14 ...
Страница 25: ...6 Explosion View And Parts List 6 1 Indoor Unit Explosion View Of 24 Fig 1 E type Explosion View ...
Страница 27: ...Fig 2 1 26 6 Explosion View And Parts List 6 3 door Unit Explosion View Of Out ...
Страница 44: ......