background image

7. Set time.

8. Lock / Unlock the 

screen by holding 

the center button 

for 3 seconds.

9. Turn off the device 

after massage.

10. Remove the pads 

(do not pull the 

wire).

Содержание USER MANUAL

Страница 1: ...e sure to read the user manual before use so you are aware of any contraindications and warnings If you re not sure whether this device is suitable for you consult your doctor first Operation Note Do not use it while charging 1 Clean the applica tion areas 2 Connect the lead wire to a pair of electrode pads and the device keep the unit off Quick Guide ...

Страница 2: ...3 Paste the pads to the skin firmly 4 Turn on the device 5 Choose a mode and sub mode 6 Adjust intensity ...

Страница 3: ...7 Set time 8 Lock Unlock the screen by holding the center button for 3 seconds 9 Turn off the device after massage 10 Remove the pads do not pull the wire ...

Страница 4: ...1 Do not use the unit in the shower sleeping driv ing operating machinery or during any electrical ly stimulated activity 2 Theelectrodepadsshouldnotbeoverlappednor placed on the artery broken skin or on the same side of the arm leg ...

Страница 5: ...USER MANUAL Model AS1080 TENS EMS Device Relaxation Anywhere Anytime Device Name TENS EMS Device ...

Страница 6: ...6 5 2 Pad Placement Suggestion 18 6 TENS Electrode Pads Pads Holder 20 6 1 Features 20 6 2 Instruction 21 6 3 Electrode Pads Care and Storage 22 6 4 Electrode Pads Precautions 23 7 Safety Precautions Warnings 24 7 1 Prohibited Conditions 24 7 2 Prohibited Individuals 25 7 3 Prohibited Areas 25 7 4 Prohibited Activities 26 8 Trouble Shooting 26 9 Features 29 10 Symbols 30 11 Certification 31 12 Cus...

Страница 7: ...he skin to nerves to modify your pain perception TENS is used for temporary relief of pain associated with sore and aching muscles in the shoulder waist back neck upper extremities arm and lower ex tremities leg due to strain from exercise or normal household work activities 2 Standard Package AUVON TENS EMS Massager Pin Pads Pads Holder Pouch Set of Electrode Wires 1 2 Wire USB C Port User Manual...

Страница 8: ...Email support iauvon com 8 3 Illustrations of the Device ...

Страница 9: ...e Knead Modes Cupping Modes Deep Tissue Modes Mode Selection Intensity Decrease Time Selection Acupuncture Modes Tapping Modes Scraping Modes Adjustable Intensity Intensity Increase Center Button Two output connectors On Off Switch USB Port ...

Страница 10: ...t all the modes and select the one that s most comfortable for you For initial use the intensity should be set between 1 3 If you feel the intensity is weak in 1 2 minutes gradually increase it and select the most comfortable setting It is recommended to use the device for 20 30 minutes and to stop using it when pain is relieved 4 2 How to Use 1 Clean and dry the application area and do not attach...

Страница 11: ... com 11 2 Take out the pads from the sealed packaging and keep the packaging for future storage 3 Connect one pair of electrode pads to one lead wire and plug the other end of the wire into the A or B output of the device ...

Страница 12: ...age area and press the edge of the elec trode pads firmly on your skin to make sure full contact For additional relief use the second port with two additional pads on the area Make sure the unit is off when you attach the pads NOTE Each lead wire needs to be connected to a pair of pads 2 pads or it won t work 5 Turn on the device by sliding the on off switch on the top of the unit ...

Страница 13: ...the lowest setting with each mode selection 7 To increase or de crease the intensity of the selected channel please press the button Includes 20 Lev els each indicator bar represents 2 strength levels For initial use the intensity should be set between 1 3 If you feel the intensity is weak in 1 2 minutes gradually increase it and select the most comfortable setting ...

Страница 14: ...s device for more than 30 minutes at a time Stop using it if the pain is relieved 9 Long press the T button for 10 seconds if all the icons on the screen stop flashing then you can adjust the backlight brightness low medium and highlight with the button and adjust the backlight duration 10s 30s 60s with the but ton the backlight duration will be displayed on the top left of the screen The screen w...

Страница 15: ...n for seconds 2 Grab a corner of the electrode pad and slowly peel it away from the skin do not pull the wire and avoid touching the gel as much as possible 3 Place the sticky side of the pad on the transparent film or pad holder and remove the lead wire connec tor from the electrode pads gently 4 Store the electrode pads in the storage bag and reseal tightly to prevent them from dry out Store the...

Страница 16: ...box appears and blinks and the time display value will update to the percentage of charge All other icons are removed and not displayed Charging Parameters Input 100 240V AC 50 60Hz 0 25A Output DC 5V 3 The machine does not work while charging Nor mal charging will last approximately 2 3 hours TIP Charge the unit at least every 3 months if it is not used regularly 5 Mode Instruction 5 1 Mode Descr...

Страница 17: ... Pulse Width μs 5 2 7 30 240 6 1 6 13 7 240 7 41 6 240 8 2 240 49 240 9 43 240 10 43 240 11 43 240 12 5 20 5 240 13 59 240 14 57 240 15 5 240 16 10 55 240 17 42 240 18 2 7 32 240 40 240 42 240 19 2 240 100 240 20 5 240 60 21 59 240 22 59 240 23 47 240 24 67 240 90 ...

Страница 18: ...2 Pad Placement Suggestion Neck Pain Shoulder Pain Modes 5 16 17 18 Modes 1 2 3 4 8 15 16 19 Tennis Elbow Carpal Tunnel Syn drome Modes 5 6 10 16 Modes 1 4 7 22 Back Pain Sciatica Modes 8 13 14 15 16 23 24 Modes 2 13 14 18 19 23 24 ...

Страница 19: ...port iauvon com 19 Hip Thigh Pain Period Pain Modes 1 2 3 4 6 7 12 15 20 Modes 13 14 19 Knee Pain Claf Pain Modes 9 11 12 17 21 23 Modes 1 2 3 4 6 7 23 24 Ankle Pain Plantar Fasciitis Modes 3 5 15 Modes 1 2 3 4 ...

Страница 20: ...m 20 6 TENS Electrode Pads Pads Holder 6 1 Features Widely compatible for pads in different sizes The salient points are designed specially to lessen damage to the pads High quality ABS material to make sure you use it safely ...

Страница 21: ...Email support iauvon com 21 6 2 Instruction Stick the electrode pads on the holder to avoid getting dust Wind the thread around the holder for easy use as shown Step 1 Step 2 ...

Страница 22: ...ode pads lifespan drop a few drops of water on the sticky side and dry it naturally on the pad holder with the gel side facing up then it will become sticky again Excessive water will de crease the stickiness Cover the sticky side of the electrode pads with the transparent film and store them in the sealed bag Dust on the gel will decrease the stickiness of the electrode pads Step 3 Store the elec...

Страница 23: ...or throat broken excessively swollen and red infected and inflamed or rash skin e g phlebitis thrombophlebitis varicose veins Do not apply ointment or solvent to the electrode pads or the area where to be used The electrode pads should not touch metal objects like belt buckles necklaces or other metal worn un der clothes Please refer to the following principles when using 1 During use please ensur...

Страница 24: ...based on personal feeling Attaching the pads to one area for a long time will make the skin un breathable and lead to redness or itching If your skin is irritated during the use stop using the electrode pads and consult your doctor 6 Please turn off the unit first and remove the pads from your skin or you will be shocked 7 When removing the electrode pads grab the cor ner of the electrode pad with...

Страница 25: ...tronic device 7 3 Prohibited Areas Any part of the head or face Any part of the throat and its vicinity can cause severe muscle spasms and lead to choking The heart and its vicinity or genital area Open wounds or rash areas Swollen red infected or inflamed areas Areas of skin erosion caused by varicose veins phlebitis thrombophlebitis and thrombosis Sites on or near cancerous lesions Skin that lac...

Страница 26: ...n does not solve the problem please contact customer service support iauvon com Problem Possible Cause Solution The unit is on but no pulse is felt from the pads Only apply 1 electrode pad to the mas sage area Attach a pair of electrode pads of the same channel to the massage area Poor connec tion between the pads and the device Connect the both ends of the lead wires to the pads and the device ti...

Страница 27: ...to change the position of the electrode pads Poor wire connection Plug the wire into the output port completely If it does not work replace the wire and try again Power cuts off during use Low battery Charge the battery and a full charge may take 2 3 hours The default timer is fin ished Set the time again with the T button from 10 60 minutes ...

Страница 28: ... turn it on again The power button cannot move The button may be stuck please shake the body and then try to dial the button The power button fails If the button is already in the ON position toggle it to the OFF position and try to restart Can t adjust the time intensity mode The screen is locked If there s a lock icon on the to middle of the screen please press and hold the Button for 3 seconds ...

Страница 29: ...or decrease the intensity The electrode pad surface is worn out When the pad has the follow ing conditions please do not use and promptly replace it gel melting patch does not stick pads deformed gel damaged 9 Features Mecha nism Technical Description Wave Form Symmetrical Bi Phasic Square Pulse Voltage 0 110V Load 500 ohm Power source 180mA lithium battery Size 9 5cm L x5cm W x1cm H ...

Страница 30: ...sure 700Hpa 1060Hpa Remark There may be a 5 tolerance of all parameters and 20 tolerance of amplitude voltage 10 Symbols Symbol Meaning Attention consult accompanying documents BF Isolated Applied Part Class II equipment Disposal in accordance with Directive 2002 96 EC MANUFACTURER ...

Страница 31: ... clearance from hazardous parts and protected against solid foreign objects of 12 5 mm Ф and great er The second number Protected against vertically falling water drops when enclosure is tilted up to 15º Vertically falling drops shall have no harmful effects when the enclosure is tilted at any angle up to 15 on either side of the vertical 11 Certification The device complies with following normati...

Страница 32: ...Email support iauvon com 32 12 Customer Service 24 Month Limited Warranty Lifetime Technical Support 1 678 829 7256 support iauvon com Auvon US AS1080 24mode sms v1 0 220726 ...