Interfacing AutroMaster_5000
Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE,
Rev. J, 2011-12-06,
Autronica Fire and Security AS
5.3.3 Application with Fibre Optic Cabling
Detail connection drawing
RX
TX
Converter
Fibre Optic
Maximum
1000-2000m
HUB
Twisted
Pair
Cable
RX
TX
Converter
Twisted
Pair
Cable
Twisted
Pair
Cable
Power
Fire Brigade Msg
Fire Vent Activated
Fire Ext Activated
0
A L A R M
?
C
9
8
7
6
5
4
3
2
1
Silence Buzzer
Silence Sounders
Reset
More Alarms
Prewarning
Early Warning
System Fault
Function Disabled
Test
Fault
Self Verify
General Alarm
RX
TX
Converter
Fibre Optic
Maximum
1000-2000m
HUB
Twisted
Pair
Cable
RX
TX
Converter
Twisted
Pair
Cable
Twisted
Pair
Cable
Power
Fire Brigade Msg
Fire Vent Activated
Fire Ext Activated
0
A L A R M
?
C
9
8
7
6
5
4
3
2
1
Silence Buzzer
Silence Sounders
Reset
More Alarms
Prewarning
Early Warning
System Fault
Function Disabled
Test
Fault
Self Verify
General Alarm
AutroMaster 5000
(master)
AutroMaster 5000
(slave)
BS-320
BC-320
HUB
AUTROLON
RING 1
Detection
Loop
BN-300
BN-310
Alarm, Fault Warning
BSD-310
2K End Resistance
Note:
Make sure that connections are galvanically isolated.
Twisted
Pair
Cable
BS-320
Power
Fire Brigade Msg
Fire Vent Activated
Fire Ext Activated
0
A L A R M
?
C
9
8
7
6
5
4
3
2
1
Silence Buzzer
Silence Sounders
Reset
More Ala rms
Prewarning
Early Warning
System Fault
Function D isabled
Test
Fault
S elf Verify
Gene ra l Alarm
BS-320
AUTROLON
RING 2
BS-320
BC-320
BS-320
2K End Resistance
Detection
Loop
BN-310
BN-300
BSD-310
Twisted
Pair
Cable
Alternative 1
Fibre Optic
Maximum
1000-2000m
Alternative 1
Fibre Optic
Maximum
1000-2000m
Twisted
Pair
Cable
Converter
Converter
Converter
Twisted
Pair
Cable
Twisted
Pair
Cable
Converter
Alternative 1
Fibre Optic
Maximum
1000-2000m
Power
Fault
Self Verify
Power
Fire Brigade Msg
Fire Vent Activated
Fire Ext Activated
0
A L A R M
?
C
9
8
7
6
5
4
3
2
1
Silence Buzzer
Silence Sounders
Reset
More Ala rms
Prewarning
Early Warning
System Fault
Function D isabled
Test
Fault
S elf Verify
Gene ra l Alarm
Power
Fire Brigade Msg
Fire Vent Activated
Fire Ext Activated
0
A L A R M
?
C
9
8
7
6
5
4
3
2
1
Silence Buzzer
Silence Sounders
Reset
More Ala rms
Prewarning
Early Warning
System Fault
Function D isabled
Test
Fault
S elf Verify
Gene ra l Alarm
Power
Fire Brigade Msg
Fire Vent Activated
Fire Ext Activated
0
A L A R M
?
C
9
8
7
6
5
4
3
2
1
Silence Buzzer
Silence Sounders
Reset
More Ala rms
Prewarning
Early Warning
System Fault
Function D isabled
Test
Fault
S elf Verify
Gene ra l Alarm
Power
Fire Brigade Msg
Fire Vent Activated
Fire Ext Activated
0
A L A R M
?
C
9
8
7
6
5
4
3
2
1
Silence Buzzer
Silence Sounders
Reset
More Ala rms
Prewarning
Early Warning
System Fault
Function D isabled
Test
Fault
S elf Verify
Gene ra l Alarm
Power
Fire Brigade Msg
Fire Vent Activated
Fire Ext Activated
0
A L A R M
?
C
9
8
7
6
5
4
3
2
1
Silence Buzzer
Silence Sounders
Reset
More Ala rms
Prewarning
Early Warning
System Fault
Function D isabled
Test
Fault
S elf Verify
Gene ra l Alarm
Power
Fault
Self Verify
BS-320
Converter
Converter
Содержание Autro Safe BC-320