Breath Test Procedure

Before providing a sample

®

1. Your Autowatch WAB 100  reacts very specifically to the presence of alcohol in the breath. 

However, it can be affected by, for example, use of mouthwash or the application of perfume 
and aftershave immediately before taking your sample. All of these products contain alcohol 
and their presence may elevate the results determined by the instrument.

2. Similarly, elevated results can occur if you have consumed alcohol up to 20 minutes before 

providing a sample. This is because your mouth may still contain residual alcohol from the 
last drink.

3. Smoking within up to two minutes of providing a sample may also produce erroneous 

results.

WAB  Switch-on

To switch on, press and release the Small Button. A confirming beep will sound, followed by a 
series of screens showing:

Autowatch

Instrument Serial Number

Instrument temperature

Time

Date

Next scheduled service date

Please Wait

2

Fit Mouthpiece

Take Sample

Meanwhile, the WAB automatically checks its operating parameters.  
When the WAB is ready to take a sample a further single beep will 
sound, followed by the message

We strongly recommend that you take the WAB with you when you leave the 
vehicle.  This will then not only act as an additional security system for your 
vehicle, but will also help to prevent  the WAB from being exposed to temperature 
extremes.

PROVIDING A BREATH SAMPLE

Take a deep breath , seal your lips around the 
wide end of the mouthpiece and blow into it with 
moderate force. The instrument will detect your 
breath flow and will emit a continuous tone as 
long as you are blowing correctly. Once sufficient 
breath has been blown the tone will stop and a 
double click will be heard followed by two rapid 
beeps. Once you have heard the two beeps then 
stop blowing.

Ensure that your Service/Fitment Centre fully 
demonstrates the correct blowing technique 
of the WAB.

NOTE

The WAB is equipped with highly sophisticated methods of detecting 

sample tampering.  Any attempt to start your vehicle without providing an 
unadulterated human breath sample will be logged within the system and you may 
be required to explain your actions at a later date.

With the ignition switched off the 

 LED will be flashing.

RED

ALCOHOL INTERLOCK 

OPERATING PROCEDURE FLOW CHART

Breath sample taken

is above accepted

alcohol level

Breath sample taken

is below accepted

alcohol level

On/Off
Switch

PASS

FAIL

The breath sample result

together with date and time

will be recorded on the WAB’s

non volatile memory

The breath sample result

together with date and time

will be recorded on the WAB’s

non volatile memory

The 

 LED will now flash

rapidly for 2 Secs then 

extinguish and remain off

 to indicate that the VBS has 

received the unblocking 

signal from the WAB

RED

The 

 LED will 

continue to Flash 

indicating that the VBS 

has received the blocking

 signal from the WAB

RED

This now causes the VBS

to unblock and therefore the 

vehicle can be started

Failure to start

the vehicle within

the preset time period

will cause the VBS

to block the vehicle.

The VBS remains blocked 

and the vehicle 

cannot be started

PASS

FAIL

Turn on the WAB by pressing the Red button

Override 

Button

Internal

Buzzer

WAB

VBS

Once the WAB has settled 

it will be ready to 

accept a breath sample

The WAB will go through 

its start up routine

Blow into

WAB following the 

operators manual

procedure

WA

B 10

0