Breath Test Procedure
Before providing a sample
®
1. Your Autowatch WAB 100 reacts very specifically to the presence of alcohol in the breath.
However, it can be affected by, for example, use of mouthwash or the application of perfume
and aftershave immediately before taking your sample. All of these products contain alcohol
and their presence may elevate the results determined by the instrument.
2. Similarly, elevated results can occur if you have consumed alcohol up to 20 minutes before
providing a sample. This is because your mouth may still contain residual alcohol from the
last drink.
3. Smoking within up to two minutes of providing a sample may also produce erroneous
results.
WAB Switch-on
To switch on, press and release the Small Button. A confirming beep will sound, followed by a
series of screens showing:
Autowatch
Instrument Serial Number
Instrument temperature
Time
Date
Next scheduled service date
Please Wait
2
Fit Mouthpiece
Take Sample
Meanwhile, the WAB automatically checks its operating parameters.
When the WAB is ready to take a sample a further single beep will
sound, followed by the message
:
We strongly recommend that you take the WAB with you when you leave the
vehicle. This will then not only act as an additional security system for your
vehicle, but will also help to prevent the WAB from being exposed to temperature
extremes.
PROVIDING A BREATH SAMPLE
Take a deep breath , seal your lips around the
wide end of the mouthpiece and blow into it with
moderate force. The instrument will detect your
breath flow and will emit a continuous tone as
long as you are blowing correctly. Once sufficient
breath has been blown the tone will stop and a
double click will be heard followed by two rapid
beeps. Once you have heard the two beeps then
stop blowing.
Ensure that your Service/Fitment Centre fully
demonstrates the correct blowing technique
of the WAB.
NOTE
The WAB is equipped with highly sophisticated methods of detecting
sample tampering. Any attempt to start your vehicle without providing an
unadulterated human breath sample will be logged within the system and you may
be required to explain your actions at a later date.
With the ignition switched off the
LED will be flashing.
RED
ALCOHOL INTERLOCK
OPERATING PROCEDURE FLOW CHART
Breath sample taken
is above accepted
alcohol level
Breath sample taken
is below accepted
alcohol level
On/Off
Switch
PASS
FAIL
The breath sample result
together with date and time
will be recorded on the WAB’s
non volatile memory
The breath sample result
together with date and time
will be recorded on the WAB’s
non volatile memory
The
LED will now flash
rapidly for 2 Secs then
extinguish and remain off
to indicate that the VBS has
received the unblocking
signal from the WAB
RED
The
LED will
continue to Flash
indicating that the VBS
has received the blocking
signal from the WAB
RED
This now causes the VBS
to unblock and therefore the
vehicle can be started
Failure to start
the vehicle within
the preset time period
will cause the VBS
to block the vehicle.
The VBS remains blocked
and the vehicle
cannot be started
PASS
FAIL
Turn on the WAB by pressing the Red button
Override
Button
Internal
Buzzer
WAB
VBS
Once the WAB has settled
it will be ready to
accept a breath sample
The WAB will go through
its start up routine
Blow into
WAB following the
operators manual
procedure
WA
B 10
0