Table 3 – Conductivity coefficients of the air duct parts
Number
Part
Single Dual
1
Grille Ø60mm 30°
5
1
2
Flange Ø60mm
0
0
3
Air pipe Ø60mm, 1m
1
2,5
4
Grille for 2D casing
0
0
5
Air pipe Ø60mm, bend 90°
12
12
6
Y-shape adapter for air pipe Ø60mm with 45°
-
10
7
T-shape adapter for air pipe Ø60mm
-
2,5
8
Y-shape adapter with a control valve 3*Ø60mm
-
6
9
Adjustable grille Ø60mm
32
8
10
Deflector closable Ø60mm
25
5
11
Inlet grille for 44D casing
0
0
12
Outlet grille for 44D casing
0
0
13
Air pipe adapter for PLANAR 44D Ø96-Ø90mm
0,4
0,4
14
Air pipe Ø90mm, 1m
10
2,5
15
Air pipe Ø90mm, bend 90°
12
12
16
Flange Ø90mm
0
0
17
Grille Ø75/90mm 30°
6
1
18
Y-shape adapter for air pipe, 3*Ø90mm, 45°
-
3
19
Y-shape adapter with a control valve 3*Ø90mm
-
12
20
T-shape adapter for air pipe 3*Ø90mm
-
6
21
Deflector closable, Ø75/90mm
25
5
22
Transition for air adapters from Ø90mm to Ø75mm
33
0
23
Y-shape adapter for air pipe, from Ø90 to 2*Ø75mm, 120°
-
9
24
Air pipe Ø75mm, 1m
12
3
25
Air pipe Ø75mm, bend 90°
12
12
26
Y-shape adapter for air pipe Ø75mm
-
10
27
Y-shape adapter for air pipe Ø75mm, 45°
-
6
28
T-shape adapter for air pipe Ø75mm
-
2
29
Flange Ø75mm
0
0
30
Grille Ø75mm
5
1
31
Transition for air adapters from Ø75mm to Ø60mm
33
0
32
Y-shape adapter for air pipe, from Ø75 to 2* Ø60mm
-
9
33
Air pipe connector, Ø90mm
0
0
34
Air hose connector Ø75mm
0
0
0 = there is no conductivity coefficient for this part