If
AUX 3
is programmed for a 1-second
TRUNK
signal,
you will need to hold the
TRUNK
button down for 3
seconds in order to activate the Trunk.
The following diagrams show how to use this output for Positive or Negative Trunk release systems.
Trunk 2 Output with Disarm / Rearm Pulse
(Mode 3, Function 2, Option 3.)
When the Trunk 2 Option is selected (Mode 3, Function 2, Option 3), a Disarm pulse
will be sent before the Trunk is popped. An Arm pulse will be sent 4 seconds later. This option is overridden when the
Zone 3 Bypass
is used as a Trunk pin (Mode 3, Function 5, Option 1).
Programmable External Trigger
(Mode 3, Function 5.)
The External Trigger wire can be connected to a Trunk Pin-switch generating a negative signal
when the Trunk is open.
Option 1 –
Zone 3 sense
:
When the External Trigger wire is programmed as a Zone 3 Sense wire, pressing
TRUNK
will
send a 1-second Disarm pulse. If Zone 3 is detected (ground), a Rearm pulse will be sent 5 seconds after Zone 3
closes. If Zone 3 is unchanged (no ground), a Rearm pulse will be sent 4 seconds after the button is pressed (Disarm
is sent only if the system was previously locked and armed).
If Secure Lock is enabled, a Lock pulse and a Rearm
pulse will be sent.
Option 2 (Engine Start/Stop – by default):
When the External Trigger wire is programmed to Trigger the starter, a
ground pulse on this line will start or stop the Engine.
Option 3 (Key Sense):
When the External Trigger wire is programmed as Key Sense, when a Key is detected in the
Ignition Switch (negative signal) the Starter Kill will not be rearmed even when it is set to Passive Mode. If Secure Lock
is programmed, Lock and Rearm will not be activated while Key Sense is active.
Option 4 (Smart Ignition Lock):
When the External Trigger wire is programmed as Dome Light Monitor / Smart
Ignition Lock (while the Ignition Lock Option or the Lock Only Option is enabled), the Doors will be relocked when the
brake is pressed if a Door has been opened and closed.
Note
When External Trigger is set to Option 1 (Zone 3), a
Disarm pulse will be sent with
TRUNK
regardless of the
AUX 3
/ Zone 3 settings in Mode 3, Function 2.
Home Valet™
(Mode 3, Function 1.)
This amazing safety feature allows the user to remotely place the system into a no-start mode:
if the vehicle is parked indoors there is no danger it will start accidentally by Remote Control or External Trigger.
To activate Home Valet:
•
Press lock + start/stop the Transmitter will beep once and the Parking Lights will flash once then within 3 sec
press lock + start/stop again, Parking Lights will stay on for 3 seconds then shut off, the Transmitter will
beep 3 times.
Note:
Once Home Valet is activated, the vehicle will not start
by Remote Control or External Trigger until the Ignition
Key is turned to the
IGNITION ON (RUN)
position again.
Ground Out When Running
This is a 500 mA constant ground output when the vehicle is running. It becomes active 1 second before remote
Ignition On, and shuts off as soon as the system is shut down. It can be used to activate external relays, bypass kits or
external modules.