15
8 Window function, distance P1 > P2
AU011-AU013
Start programming mode of the device.
(7.1)
►
Object in position P1.
►
Connect teach input approx. 1 s.
> LED flashes (2.5 Hz).
►
Object in position P2.
►
Connect teach input approx. 1 s.
> LED flashes (4 Hz).
> If programming is not completed suc-
cessfully, the LED does not flash and the
instrument returns to the previous setting.
AU014-AU018
Start programming mode of the device. (7.2)
►
Object in position P1.
►
Press button once 1 s.
> LED flashes (2.5 Hz).
►
Object in position P2.
> Press button once 1 s.
> LED flashes (4 Hz).
> If programming is not completed
successfully, the LED does not flash and
the instrument returns to the previous
setting.
Output response of
analogue output
X: Distance
Y: Comportamento dell‘uscita
②:
OUT2 (analogue output)
B: Blind zone
P1: Setting point 1
P2: Setting point 2
B P2
P1
Y
X
Y
X
1
2
B P2
P1
Y
X
Y
X
1
2
Output response of the switching
/ analogue output
X: Distance
Y: Output response
①:
OUT1 (switching output)
②:
OUT2 (switching output / analogue output)
B: Blind zone
P1: Setting point 1
P2: Setting point 2
UK
UK