INSTALLATION INSTRUCTIONS
PIT INSTALLATION -- continued
DANGER
!
HIGH VOLTAGE!!
–
Disconnect and/or lock out the electrical
supply to the power unit per OSHA regulations prior to any
installation or maintenance being performed.
5. The base frame of the turntable has pre-drilled holes for lagging it securely to the
floor. Mark holes, drill, and install with anchors. Turntables with oversize platforms
have minimum pull out requirements of 2,000 lbs. for each anchor.
6. Make the permanent electrical connections and operate the turntable through a few
cycles.
WARNING!
The turntable base MUST be attached securely to the lift
platform before operating the turntable.
NOTE
: Turntables that have platform sizes larger than the lifts to which they are
attached must have toe protection, such as beveled-toe guards.
7. A home position limit switch is mounted to the turntable base and wired to the lift
controller. This will ensure that the turntable (in
home position
) is positioned
exactly over the pit opening before it is lowered into the pit.
Home position for the
turntable allows 1” clearance between each side of the turntable and the pit
curb angle.
8. Lower the lift & turntable combination into the pit and check for proper lowered
height.
9. Make the permanent electrical connections and operate the combination through a
few cycles. Check to ensure that the lift will not lower until the turntable platform is in
home position
(for four-sided platform).
CLEAN UP
1. Clean up any debris from the area. A clean installation makes a good impression
and creates a much safer environment!
2. Touch-up paint is available from
Autoquip
for repair of damaged paint surfaces.
17
Содержание SRP
Страница 21: ...Figure 7 SRP Electrical Schematic 115V 1PHASE CW Rotation w LIMIT SWITCHES 21...
Страница 22: ...GENERAL MAINTENANCE Figure 8 SRP Electrical Schematic 115V 1PHASE CW CCW Rotation w LIMIT SWITCHES 22...
Страница 23: ...GENERAL MAINTENANCE Figure 9 SRP Electrical Schematic 230V 1PHASE CW CCW Rotation w LIMIT SWITCHES 23...
Страница 24: ...GENERAL MAINTENANCE Figure 10 SRP Electrical Schematic 208 230 460V 3PHASE CW Rotation w LIMIT SWITCH 24...
Страница 28: ...GENERAL MAINTENANCE Figure 14 SRP SRPRB Electrical Schematic VFD 208 230V 3PHASE W LIMIT SWITCH CW ROTATION 28...
Страница 29: ...GENERAL MAINTENANCE Figure 15 SRP SRPRB Electrical Schematic VFD 208 230 460V 3PHASE CW CCW ROTATION 29...
Страница 30: ...GENERAL MAINTENANCE Figure 16 SRPA Pneumatic Schematic CW CCW Rotation 30...
Страница 31: ...GENERAL MAINTENANCE Figure 17 SRPA Pneumatic Schematic W LIMIT SWITCHES CW CCW Rotation 31...
Страница 36: ...REPLACEMENT PARTS LIST SRPA AIR Motor Turntable Parts Figure 20 Pneumatic Motor SRPA Base Layout 36...