background image

3

Basic Functions

1.

To start the heater by using car’s remote control key press “Lock” button 3
times. Time intervals between presses must not exceed 20 seconds. The 
excess of time interval restarts the counter of “Lock” button presses. Car 
confirms commands reception with hazard signals flashing.

2.

To stop the heater by using car’s remote control key press “Unlock” button 3
times. Time intervals between presses must not exceed 20 seconds. The 
excess of time interval restarts the counter of “Unlock” button presses. Car 
confirms commands’ reception with hazard signals flashing.

3.

It is possible remotely disable startups of the heater, programmed in the CIP. 
Use remote control key to send stop command when the heater is idle. 
Starting the heater any way or turning the ignition to “on” position enables 
CIP timers again. 

4.

Additionally installed button can be connected to the module. The button is 
used for immediate start and stop of the heater. Button pressing changes 
heater condition to another one: switches off operated heater or switches on 
idle heater.

5.

If additional remote control connected to the RCP, its functionality depends
on connection schemes, module settings and the remote control possibilities. 
See remote control documentation for details.

Additional Functions

By default RCP adjusted to perform only basic functions, such as start and 

stop of the heater from the remote control key. To turn on the additional functions 
such as battery monitoring, flashing with direction indicators in rearview mirrors, 
etc. enter the module into Setup mode and activate corresponding setup item (see 
settings table 3).

Programming button and the brake pedal are used to enter Setup mode and 

to the settings change. Use additionally installed button as programming button. 

It is necessary to stop the engine and the heater before. Turn the ignition on

by holding engine start button for 2 seconds at least, then press and hold the brakes
pedal. Press the programming button for 3 times (each time hold the button until 
LED goes off, about 1.5 seconds). The LED will go on confirming the Setup mode 
entering. Release the brakes pedal.

Each setup item in the settings table is a 3-digit code. To enter a digit of a 

code, shortly press the programming button so many times, as corresponds to a 
digit. The LED confirms each button press by going off briefly. To complete a 
digit entering, press and release brakes pedal. The module confirms it with one
brief flash of the LED. When all three digits entered, the module checks the code 
for validity and confirms valid code with double LED flashing.

Содержание RCP-V5

Страница 1: ...Autoplugin RCP V5 Version 7 1 Technical Description User Manual Rev A...

Страница 2: ...olvo S90 2016 V90 2016 or XC90 2015 The device controls the heater via CAN bus Module Possibilities Set of inputs for additional remote control connection Set of outputs with programmable heater statu...

Страница 3: ...ontrol possibilities See remote control documentation for details Additional Functions By default RCP adjusted to perform only basic functions such as start and stop of the heater from the remote cont...

Страница 4: ...eat mode 1 1 1 Not adjusted 1 1 2 40 minutes 1 1 3 50 minutes 1 1 4 60 minutes 1 1 5 70 minutes 1 1 6 80 minutes 1 1 7 90 minutes 1 1 8 100 minutes 1 1 9 120 minutes 1 2 Limitation of heater 1 cycle o...

Страница 5: ...er startup 4 1 5 In 25 minutes after heater startup 4 1 6 In 30 minutes after heater startup 4 1 7 In 40 minutes after heater startup 4 1 8 In 50 minutes after heater startup 4 1 9 In 60 minutes after...

Страница 6: ...s off potential 7 5 3 Flashers control signal double impulses with the frequency adjusted by 6 7 applying settings 6 3 6 5 3 7 5 4 Engine runs potential 7 5 5 Engine runs RPM impulses 7 5 6 Disable th...

Страница 7: ...eater is idle positive impulse given to the input cancels the timer start of the heater programmed in the CIP Table 1 X1 pin number Signal Name Polarity Wire colour 1 Heater_off White 2 Heater_off Gre...

Страница 8: ...mpulse X1 4 Heater_on 1 The input can be used to switch the heater on by the impulse of negative polarity the input Heater_on in that case has to be connected to the Power The heater is started by the...

Страница 9: ...ntrol if remote is compatible to alerts receiving The assignment of this output is defined by the setting 7 4 When programmed event is occurred the impulse of negative polarity with 1 second duration...

Страница 10: ...Appearance Solutions 2 No answer from the heater followed the start command Outer temperature displayed by the CIP is higher than 14 Celsius degrees The heater operates only at temperatures below 15...

Страница 11: ...There is a problem with module connection to the CAN bus Check for the connection 9 Settings error Settings have been stored in RCP s memory incorrectly Reset the settings 8 1 1 readjust the module 1...

Страница 12: ...12 Autoplugin ES www autoplugin ru...

Отзывы: