Autoplugin Key-V4 Скачать руководство пользователя страница 6

6

module start the 
heater in pre-heat 
mode 

3.1.4

11.9V 

3.1.5

12.0V

3.1.6

12.1V

3.1.7

12.2V

3.1.8

12.3V

3.1.9

12.4V

3.2.

Minimal battery 
voltage that lets the 
module keep 
operating the heater 
in pre-heat mode

1

3.2.1

* Not adjusted

3.2.2

11.4V

3.2.3

11.5V 

3.2.4

11.6V 

3.2.5

11.7V

3.2.6

11.8V

3.2.7

11.9V

3.2.8

12.0V

6. 

Indication 
with
direction 
indicators in 
rearview 
mirrors

6.1.

Indication of 

heater startup 

6.1.1  *

Off

6.1.2  

Five flashes

6.2.

Indication of 

command reception 
from a remote 
control

6.2.1  *

Off

6.2.2  

Three flashes

6.3. 

Indication of 

heater operation, 
when starting 
source is a remote 
control

6.3.1 *

Off

6.3.2 

On

6.4. 

Indication of 

heater operation, 
when starting 
source is the CIP
(direct start)

6.4.1 *

Off

6.4.2 

On

6.5. 

Indication of 

heater operation, 
when starting 
source is other than 
specified in 6.3,6.4

6.5.1 *

Off

6.5.2 

On

8.

Service 
menu

8.1.

Default Settings

8.1.1

Apply factory settings

* Factory setting

Recommended settings marked in Italics 

1

–The module turns off the heater if battery voltage lowers to the adjusted limit

Содержание Key-V4

Страница 1: ...Autoplugin Key V4 Version 9 5 User Manual Rev A...

Страница 2: ...ossibilities 3 Package Content 3 Connection 3 Basic Functions 4 Additional Functions 4 Troubleshooting 7 Glossary CAN Control Area Network digital network for data transfer in vehicles CIP Combined In...

Страница 3: ...tection of the main battery from discharging inspecting voltage level and time of autonomous operation of the heater Package Content 1 Autoplugin Key V4 cartridge 2 User Manual brochure Connection The...

Страница 4: ...s necessary to stop the engine and the heater before Turn the ignition on by holding engine start button for at least 2 seconds then press and hold the brakes pedal Further press and hold for at least...

Страница 5: ...1 1 7 90 minutes 1 1 8 100 minutes 1 1 9 120 minutes 1 2 Limitation of heater 1 cycle operational time in pre heat mode 1 2 1 10 minutes 1 2 2 15 minutes 1 2 3 20 minutes 1 2 4 25 minutes 1 2 5 30 min...

Страница 6: ...6 1 2 Five flashes 6 2 Indication of command reception from a remote control 6 2 1 Off 6 2 2 Three flashes 6 3 Indication of heater operation when starting source is a remote control 6 3 1 Off 6 3 2...

Страница 7: ...diagnostics of the heater 3 Battery low The module has determined that the battery voltage is below the specified by settings items 3 1 or 3 2 Charge car s battery with special charger or start engine...

Страница 8: ...8 Autoplugin ES...

Отзывы: