1/17/03
3
SOFT TOUCH TROUBLESHOOTING CONT’D
**If the service light comes on, count the number of flashes and see below.
??
3 RED FLASHES
–
very
low amps with Salt OK
o
V1.4 or older - scaled cell or failed cell
o
Power Supply may have failed or improperly wired.
??
Check the Power Supply for Output. If you do not get a Volt reading the power
supply is bad
How to test
: The Power Supply has built in diagnostic test (See page 13 of your manual for procedures),
or use a 957B tester, put tester in Power Supply mode or a Multimeter and test for Volts.
??
Verify unit and incoming voltage match.
o
Cell cord may have failed
??
Check Cell cord for Continuity
How to test
: Use a Multi Meter and test for continuity. Center hole is the black wire.
o
Cell Failure
??
If you get
High Volts and Low
Amps
your cell is bad.
How to test
: The Power Supply has built in diagnostic test (See page 13 of your manual for procedures),
or use a 957B tester, put tester in Cell mode and test for volts and amps.
??
4 RED FLASHES
– Bad Temperature Sensor (salt will not be temperature compensated)
o
Replace Tri Sensor