background image

Selecting Cooling or Heating Mode

 

Before using the unit, the user must decide if they are using it for 
a Cooling or a Heating control. The 2 knobs on the unit are used 
to select the desired mode. 

To select Cooling:

 Connect

 

the unit to power. Rotate both knobs 

fully  COUNTER-clockwise.  After  a  couple  seconds  the  LEDs  on 
the front of the unit will start flashing On / Off. After the LEDs stop 
flashing, the selected mode is indicated by  the LED that remains 
illuminated. (*Verify the 

Cool

 mode is ON.) 

To select Heating:

 Connect

 

the unit to power. Rotate both knobs 

fully  clockwise.  After  a  couple  seconds  the  LEDs  on  the  front  of 
the  unit  will  start  flashing  On  /  Off.  After  the  LEDs  stop  flashing, 
the  selected  mode  is  indicated  by  the  LED  that  remains 
illuminated. (*Verify the 

Heat

 mode is ON.) 

*  Once  the  correct  mode  is  selected,  the  user  can  now  set  the 
desired temperature settings using the two knobs normally. 

 

Changing Settings

 

Use the knobs on the front of the unit to  adjust the DAY  and the 
NIGHT temperature settings*. The photocell will automatically use 
the  correct  setting  depending  on  the  lighting  level.  When  the 
temperature  of  the  area  exceeds  the  temperature  set-point,  the 
device connected  to  the power outlet will be activated.  Since the 
temperature  control  has  a  dead-band  setting  of  3

º

  F,  the  power 

outlet  will  remain  activated  until  the  temperature  is  lowered  by  3 
degrees F. When the outlet is powered, the 

Output ON

 LED  will 

be ON.

  

*This example describes the Cool mode. When in Cool mode, the 
setting  is  the  maximum  temperature  of the  area  to be  controlled. 
For  Heat  mode,  it  is  the  minimum  temperature  of  the  area  to  be 
controlled.

 

Содержание APCET

Страница 1: ... amperage 14 5 amps 120 VAC Temperature control range 45º to 95º F Separate Day Night settings photocell control Temperature accuracy 5 ºF Temperature dead band hysteresis 3 ºF Weight 1 lbs Dimensions 3 x 6 x 3 5 APCET Temperature Controller ...

Страница 2: ...Ds on the front of the unit will turn ON and OFF to show the user the current conditions of the APCET NOTE This unit is water resistant however Keep it away from water It is NOT WATER PROOF Installation Plug the unit into a standard NEMA 5 15 wall outlet A 120 volt power supply is required For more permanent installations the mounting tab at the top of the unit can be secured to a wall Ensure that...

Страница 3: ...d by the LED that remains illuminated Verify the Heat mode is ON Once the correct mode is selected the user can now set the desired temperature settings using the two knobs normally Changing Settings Use the knobs on the front of the unit to adjust the DAY and the NIGHT temperature settings The photocell will automatically use the correct setting depending on the lighting level When the temperatur...

Страница 4: ... unit is not being affected by other factors such as direct sunlight exposure or areas that may not have good air movement What if there is no power Ensure the unit is getting power Check the device that is connected to the unit by plugging it directly into a known power supply If the unit will not turn on and no LEDs will illuminate contact your distributor for repair and warranty issues Why are ...