Single-Phase 

Right/Left Terminal SSR

with Integrated Heatsink

SRHL1 Series

PRODUCT MANUAL

For your safety, read and follow the considerations written in the instruction 
manual, other manuals and Autonics website.

The specifications, dimensions, etc. are subject to change without notice for product 
improvement. Some models may be discontinued without notice. 

Features

• 

Rated input voltage : 10 - 30 VDCᜡ, 90 - 240 VACᜠ

• 

Rated load voltage : 24 - 240 VACᜠ, 48 - 480 VACᜠ

• 

Rated load current : 10 A, 15 A, 20 A, 25 A, 40 A

• 

Zero cross turn-on / Random turn-on models available

• 

Input indicator (green)

• 

Overheat prevention function 

 

- Rated load current 10 / 15 / 20 / 25 A: alarm indicator (red)

 

- Rated load current 40 A: alarm output indicator (red), alarm output

• 

DIN Rail or panel mount installation

ᜢ ᜧ ᜫ

Safety Considerations

• 

Observe all ‘Safety Considerations’ for safe and proper operation to avoid hazards.

• 

᜸ symbol indicates caution due to special circumstances in which hazards may occur.

᜸ Warning

  

Failure to follow instructions may result in serious injury or death.

01. 

Fail-safe device must be installed when using the unit with machinery that 

may cause serious injury or substantial economic loss.(e.g., nuclear power 

control, medical equipment, ships, vehicles, railways, aircraft, combustion 

apparatus, safety equipment, crime/disaster prevention devices, etc.)

Failure to follow this instruction may result in personal injury, economic loss or fire.

02. 

Do not use the unit in the place where flammable/explosive/corrosive gas, 

high humidity, direct sunlight, radiant heat, vibration, impact or salinity 

may be present.

Failure to follow this instruction may result in explosion or fire.

03. 

Install the unit on DIN rail or panel to use.

Failure to follow this instruction may result in fire or electric shock.

04. 

Do not connect, repair, or inspect the unit while connected to a power 

source.

Failure to follow this instruction may result in fire or electric shock.

05. 

Check ‘Connections’ before wiring.

Failure to follow this instruction may result in fire.

06. Do not disassemble or modify the unit.

Failure to follow this instruction may result in fire or electric shock.

᜸ Caution

  

Failure to follow instructions may result in injury or product damage.

01. 

Use the unit within the rated specifications.

Failure to follow this instruction may result in fire or product damage.

02. 

Use a dry cloth to clean the unit, and do not use water or organic solvent.

Failure to follow this instruction may result in fire or electric shock.

03. 

Keep the product away from metal chip, dust, and wire residue which flow 

into the unit.

Failure to follow this instruction may result in fire or product damage.

04. 

Since leakage current still flows right after turning off the power or in the 

output OFF status, do not touch the load terminal.

Failure to follow this instruction may result in electric shock.

Cautions during Use

• 

Follow instructions in ‘Cautions during Use’.

 

Otherwise, it may cause unexpected accidents.

• 

10 - 30 VDCᜡ model power supply should be insulated and limited voltage/current

 

or Class 2, SELV power supply device.

• 

Install the unit in the well ventilated place.

• 

Ground the heatsink, panel, or DIN rail. Failure to follow this instruction may result in 

electric shock.

• 

While supplying power to the load or right after turning off the power of the load, do 

not touch the body and heat sink. Failure to follow this instruction may result in burn 

due to high temperature of the surface.

• 

In order to protect the product from the short-circuit current of the load, use rapid fuse 

of which I

2

t is under the 1/2 of SSR I

2

t. When short-circuited, replace the fuse to those 

of same specification with the used rapid fuse.

• 

Install dummy resistance in parallel with the load, to keep the sum of current flowing 

in the load and dummy resistance being over SSR minimum load current.

• 

When using random turn-on model for phase control, install noise filter between the 

load and the power of the load.

• 

Do not use near the equipment which generates strong magnetic force or high 

frequency noise.

• 

This unit may be used in the following environments.

 

- Indoors (in the environment condition rated in ‘Specifications’)

 

- Altitude max. 2,000 m

 

- Pollution degree 2

 

- Installation category III