Single Phase, Integrated Heatsink Type SSR

 SRH1-1430/1430R/2430

 SRH1-1240/2240/4240

 SRH1-1260/1460/1460R

    SRH1-2460/2260/4260

 SSR Characteristic Curve

Load current [A]

Load current [A]

Load current [A]

Ambient temperature [

]

Ambient temperature [

]

0

0

40

40

60

60

20

12

20

26

0

0

10

10

20

20

30

30

40

40

50

50

60

60

70

70

80

80

Ambient temperature [

]

0

20
16

30

10

0

10 20 30 40 50 60 70 80 90

90

90

 Proper Usage

Make sure do not touch the heat sink or the unit body while power is supplied or right after load power is 

turned off. If not, it may cause a burn.

High temperature caution

Caution for using

35

35

1. Attach a heatsink and ventilate for smooth convection current. If not, congested heat transfer may cause product failure 

or malfunction.

2. For mounting multiple SSR, please keep certain installation intervals for heat prevention. For horizontal installation (when 

the heights of input part and output part are equal), it is recommended to apply less than 50% of the rated load current.

3. Make sure do not touch the heatsink or the unit body while power is supplied or right after load power is turned OFF.

    If not, it may cause a burn.

4. Connect the proper cable for the rated load current with output terminal. 

5. Use rapid fuse of which I

2

t is under 1/2 of SSR I

2

t in order to protect the unit from load's short- circuit current.

6. In case of a short-circuit please replace the fuse with a 1/2 of SSR I

2

t value specified semiconductor protective type.

7. In case that load's current is lower than SSR min. load current, connect dummy resistance to the load in parallel so as to 

make load's current higher than SSR min. load current.

8. When selecting phase control with random turn-on model, install the noise filter between load and load's source.

9. Make sure that the screw on output terminal is tightly fastened. Using the unit with loose bolt may cause product failure 

or malfunction.

10. Do not touch the load's terminal even if output is OFF. It may cause electric shock.

11. The signal input of the 4-30VDC model should be supplied by the insulated and limited voltage/current or by Class 2 

power supply.

12. Proper application environment (Avoid following environments to install)

 Where temperature/humidity is beyond the specification

 Where dew condensation occurs due to temperature change

 Where inflammable or corrosive gas exists

 Where direct rays of light exist

 Where severe shock, vibration or dust exists

 Where near facilities generating strong magnetic forces or electric noise

13. This product may be used in the following environments.

 Indoor            

 Altitude: Under 2,000m

 Pollution degree 2                  

 Installation category 