-|Transparent Guide|-

Reset

01. 

Press the [◀] + [▲] + [▼] keys for over 5 sec. in run mode, INIT flashes for 0.5 

sec. 

02. 

Press the direction keys to flash NO for 0.5 sec in turn.

03. 

Change the setting value as YES by pressing the direction keys.

04. 

Press the [MODE] key to reset all parameter values as default and to return 

to run mode. 

Error

Error display is released automatically when it is in the measured and display range.

Display Description

Troubleshooting

HHHH

Flashes when measurement input is exceeded the 

max. allowable input (110 %)

Disconnect power supply 

and check the cables.

LLLL

 01)

Flashes when measurement input is exceeded the 

min. allowable input (-10 %)

D-HH

Turns ON when display input is exceeded high-limit 

scale setting value or max. display range (9999)

Reset within the display 

range. 

D-LL

Turns ON when display input is exceeded low-limit 

scale setting value or min. display range (-1999)

F-HH

Turns ON when input frequency is exceeded the 

max. display value of measured range

-

OVER

Flashes twice when it exceeds zero range (±99) 

and returns to run mode

Reset within the zero range. 

 01)  Displays at DC input model only.

Output Operation Mode

• 

H.SET or L.SET is displayed according to the output operation mode setting. In case of output 

operation mode as OFF, H.SET and L.SET are not displayed. 

• 

When changing output operation mode, high-limit / low-limit output setting value, hysteresis

 

are reset.

MODE

Output operation

Preset output
LO ON

HI ON

GO ON

H.SET

L.SET

H

ON

OFF

H: Hysteresis

OFF

No output

lST

GO

LO

H

L.SET ≥

 

Display value -

L.SET < 

Display value

hST

HI

GO

H

-

H.SET ≤

 

Display value

H.SET > 

Display value

LhST

HI

GO

LO

H

H

L.SET ≥

 

Display value

H.SET ≤

 

Display value

L.SET < 

Display value 

< H.SET

HhST

HI

GO

LO

H

H

L.SET ≤

 

Display value

H.SET ≤

 

Display value

L.SET > 

Display value

LlST

HI

GO

LO

H

H

L.SET ≥ 

Display value

H.SET ≥ 

Display value

H.SET < 

Display value

LdST

GO

LO

H

Second L.SET 

 

Display 

value

-

L.SET < 

Display value

Time Chart

  

■ Low speed serial output (negative logic)

It outputs current display value as Low-frequency (50 Hz) type.
[Clock frequency: 50 Hz]

t: 20 ms

ta: 0.05 ms

tw: 5 ms

tb: 4.95 ms

Data

Output

ordering

DP 

DP 

DP 

DP 

Clock

Clock

Data

Latch

Display

Latch

tb

tw

ta

tb

tw

ta

t

Cn-1

Dn-1

Dn

D1

Cn

C1

1

@

3

4

1

H

1

2

H

2

3

L

4

H

5

H

6

H

7

H

8

H

9

L

10

L

11

L

12

H

13

H

14

L

15

H

16 17

18 19

20

DP D 

H H H H L

  

■ BCD Dynamic output (negative logic)

It outputs display value as BCD code.

t

t: 7.8 ms

ta: 0.5 ms

tw: 5 ms

tb: 2.3 ms

Digit signal

Digit

Data

Output data

Display

1

@

3

4

ta

tw

Data

31.2 ms

H

L

H

L

H

H

L

L

H

H

L

H

H

H

H

H

H

H

H

H

H

dot

D

C

B

A

D0

D1

D2

D3

H

L

H

H

tb