Mode Setting

RUN

[▲] + [▼] 3 sec 

Digital input

 

 01)

 

Auto

RUN

[MODE] 

Monitoring mode

[MODE] 3 sec 

[MODE] 3 sec 

Program mode

[MODE] 3 sec 

[MODE] + [◀]

Reset

[MODE]

 01) P 1-34, P2-30 Digital input key (HOLD: hold display value or ZERO: remote zero)

Monitoring Mode

• Some parameters are activated / deactivated depending on the model or setting of 

other parameters. Refer to the description of each parameter.

• If any key is not entered for 30 sec in each parameter, it returns to RUN mode.

• [MODE] key: Saves current setting value and moves to the next parameter.

• [◀] key: Changes setting digits.

• [▲], [▼] key: Changes setting values.

Parameter

Display

Defaults

Setting range

Display 

condition

M1-1 1 CH output 

value

OUt1

----

[Transmission output model]

•  Displays output value by each 

channel.

-

M1-2 2 CH output 

value

OUt2

----

M1-3 Alarm 1 value

AL1

10)0

[Alarm output model]

Temperature sensor input

: within temperature range

Analog input

: low-limit

 to 

high-limit

 scale

• 

Depending on the number of alarm 

outputs, whether to display alarm 3 / 

4 is different.

P1-20 to 27,

P2-19 to 26

Alarm 

operation / 

option:

AT1.A, 

AT2.A

M1-4 Alarm 2 value

AL2

00)0

M1-5 Alarm 3 value

AL3

10)0

M1-6 Alarm 4 value

AL4

00)0

M1-7 Display max. 

peak value

 01)

hPEK

----

Max. peak value in run mode

-

M1-8 Display min. 

peak value

 

01)

lPEK

----

Min. peak value in run mode

-

 01)  Initial max. / min. peak value is saved after 2 sec from supplying the power.

 

Reset: Press the [▼] + [▲] keys for at least 1 sec

Specifications

Model

CN-610

-

CN-640

-

Input type

 01)

Universal

-  Temperature sensor

 

: RTD, thermocouple

- Analog: voltage, current

Pulse

Display method

12-segment (selectable red, green, yellow) LCD (character size: 6.4 × 

11.0 mm), 

Graphic bar and input type / unit display part (red) LCD (character size: 

1.4 × 2.75 mm)

Display accuracy

 02)

Dependent on the ambient temperature

25 ± 5°C

± 0.2 % F.S. ± 1 digit

-10 to 20°C, 30 to 50°C ± 0.3 % F.S. ± 1 digit

Display cycle

 03)

-

Same with pulse input cycle

Sampling cycle

Temperature sensor input: 250 ms

Analog input: 100 ms

-

Unit weight 

(packaged)

≈ 160 g (≈ 301 g)

≈ 200 g (≈ 340 g)

Approval

ᜢ ᜫ

 01)  For details, refer to the input type and range.
 02)  Thermocouple, below -100 ℃: ± 0.4 % F.S. ± 1 digit

 

Thermocouple T, U: min. ± 2.0 ℃

 03) When pulse input cycle is over 10 sec, it is updated by every 10 sec.

Output

Transmission

(DC 0 - 20 mA)

Transmission

(0 - 10 VDCᜡ)

Alarm

Load resistance

≤ 600Ω

≥ 10 kΩ

-

Accuracy

± 0.3 F.S.

-

Resolution

8,000

-

Contact capacity

-

250 VACᜠ

Contact 

composition

-

5 A, 1a: 1 /

3 A, 1c: 2 /

5 A, 1a: 4 model

Power supply

100 - 240 VACᜠ ± 10 % 50 / 60 Hz  24 VDCᜡ ± 10 %

Power 

consumption

≤ 8 VA

≤ 3 W

Insulation 

resistance

≥ 100 MΩ (500 VDCᜡ megger)

Dielectric strength

Between input terminal and power terminal: 2,000 VACᜠ 50 / 60 Hz for 1 min

Vibration

0.75 mm double amplitude at frequency of 5 to 55 Hz (for 1 minute) in 

each X, Y, Z direction for 2 hours

Noise immunity

± 2 kV the square wave noise (pulse width: 1 ㎲) by the noise simulator

Memory retention

≈ 10 years (non-volatile semiconductor memory type)

Ambient 

temperature

-10 to 50 ℃, storage: -20 to 60 ℃ (no freezing or condensation)

Ambient humidity

35 to 85 %RH, storage: 35 to 85 %RH (no freezing or condensation)

Parameter

Display

Defaults

Setting range

Display 

condition

P1-1 Input type

IN-P

aMA2

• 

Refer to Input Type and Range

-

P1-2 Temperature 

unit 

 01)

UNIT

?C

 ℃, ℉

P1-1 Input 

type: 

Temp.

 

sensor

P1-3 Display unit

dUNT

?/O

 %, OFF, mV, V, mA, A, ℃, ℉

P1-1 Input 

type: 

Analog

P1-4 Low-limit 

input value

L-RG

0$00

Within input type range

•  Low-limit input value + 20 % F.S. <

 

High-limit input value

P1-5 High-limit 

input value

H-RG

2)00

P1-6

Decimal 

point 

position

dP

)0

0.0, 0.00, 0.000, 0

• 

Set the decimal point position of the 

high / low-limit scale.

P1-7 Low-limit scale

L-SC

00)0

-1999 to 9999

P1-8 High-limit scale

H-SC

10)0

P1-9 Input correction

IN-B

000

-999 to 999

-

P1-10

Low-limit 

value of 

transmission 

output 1

lOR1

0$00

[

Transmission (DC 0 - 20 mA) output model]

DC 0 - 20 mA

-

0)00

[

Transmission (0 - 10 VDCᜡ) output model]

0 - 10 VDCᜡ

P1-11

High-limit 

value of 

transmission 

output 1

hOR1

2)00

[

Transmission (DC 0 - 20 mA) output model]

DC 0 - 20 mA

-

1)00

[

Transmission (0 - 10 VDCᜡ) output model]

0 - 10 VDCᜡ

P1-12

Low-limit 

value of 

transmission 

output 2

lOR2

0$00

[

Transmission (DC 0 - 20 mA) output model]

DC 0 - 20 mA

-

0)00

[

Transmission (0 - 10 VDCᜡ) output model]

0 - 10 VDCᜡ

P1-13

High-limit 

value of 

transmission 

output 2

hOR2

2)00

[

Transmission (DC 0 - 20 mA) output model]

DC 0 - 20 mA

-

1)00

[

Transmission (0 - 10 VDCᜡ) output model]

0 - 10 VDCᜡ

P1-14 Bar display 

CH

BAR

OUT1

[

Transmission output model]

OUT1, OUT2

P1-37 User

 

level: HIGH

P1-15

Low-limit 

scale value of 

transmission 

output 1

lOU1

00)0

[

Transmission output model]

Temperature sensor input

:  within temperature range

Analog input

: low-limit

 to 

high-limit

 scale

-

P1-16

High-limit 

scale value of 

transmission 

output 1

hOU1

10)0

P1-17

Low-limit 

scale value of 

transmission 

output 2

lOU2

00)0

P1-18

High-limit 

scale value of 

transmission 

output 2

hOU2

10)0

P1-19

Input and 

transmission 

output 

extension

 02)

ExIO

5P

[

Transmission output model]

5P:  output DC 3.2 - 20.8 mA, 0 - 10.5 VDCᜡ 

out of 5 % of analog input range

10P:   output DC 2.4 - 21.6 mA, 0 - 11 VDCᜡ 

out of 10 % of analog input range

0P:  output DC 4 - 20 mA, 0 - 10 VDCᜡ in 

the analog input range

P1-1 Input 

type: 

Analog

&

P1-37 

User level: 

HIGH

P1-20 Alarm 1 

operation

AL-1

AT!A

□□□.■

[Alarm output model] □□□

AT1: high-limit alarm, AT2: low-limit

 

alarm, SBA: sensor break alarm, AT0: 

no alarm output

-

P1-21 Alarm 1 option

[Alarm output model] ■

A: standard alarm, B: alarm 

latch

C: standby sequence, 

D: alarm latch and standby sequence

• 

Enter alarm option setting mode

 

:  Operate in ‘Alarm 1 operation’ mode 

select AT1 or AT2 and input [◀] key

-

P1-22 Alarm 2 

operation

AL-2

AT@A

□□□.■

[Alarm output model]

Same as 'P1-20 / 21 Alarm 1 operation 

/ option' 

• 

Depending on the number of alarm 

outputs, whether to display alarm 3 / 

4 is different.

-

P1-23 Alarm 2 option
P1-24 Alarm 3 

operation

AL-3

AT!A

□□□.■

P1-25 Alarm 3 option
P1-26 Alarm 4 

operation

AL-4

AT@A

□□□.■

P1-27 Alarm 4 option

P1-28 Alarm output 

hysteresis

A-HY

001

[Alarm output model]

001 to 999

P1-20 to 27

Alarm 

operation

 

/ option: 

AT1.A, 

AT2.A

 01)  When changing the setting value, input type, high / low-limit scale, high / low-limit scale value of transmission 

output 1 / 2, and AL1 to 4 are reset.

 02)  0 mA, 0 VDCᜡ or less cannot be expanded. 1 VDCᜡ, 10 VDCᜡ input are available to extend only 5 %.  

Program Mode

• Some parameters are activated / deactivated depending on the model or setting of 

other parameters. Refer to the description of each parameter.

• If any key is not entered for 30 sec in each parameter, it returns to RUN mode.

• [MODE] key: Saves current setting value and moves to the next parameter.

• [◀] key: Changes setting digits.

• [▲], [▼] key: Changes setting values.

  

Universal

 input