-|Transparent Guide|-
Product Components
• Product
• 8-pin socket (output: C1, V1, R1 model)
• Instruction manual
• 11-pin socket (output: C2, V2, R2, R4 model)
Input Type Selection Switch
•
Select the input type of the universal input model.
The pulse input model does not have this input type selection
switch.
•
After selecting the input type with the switch, set the same
input specification in the input type parameter of the program
mode.
Switch
Input
mA (default
)
0 (4) to 20 mA
10V
-1 to 10 VDCᜡ
TC, RTD, mV,
±1V
Thermocouple, RTD, mV, ± 1 VDCᜡ
Dimensions
•
Unit: mm, For the detailed drawings, follow the Autonics website.
80
80
50
■ 8-pin
socket
■ 11-pin
socket
■ Panel cut-out
≥ 51
40
Ø 4.5
Ordering Information
This is only for reference, the actual product does not support all combinations.
For selecting the specified model, follow the Autonics website.
CN
-
6
❶ ❷
-
❸
❶ Input
10: Universal input
40: Pulse input
❸ Output
C1: Transmission (DC 0 - 20 mA) output × 1
C2: Transmission (DC 0 - 20 mA) output × 2
V1: Transmission (0 - 10 VDCᜡ) output × 1
V2: Transmission (0 - 10 VDCᜡ) output × 2
R1: Alarm output × 1
R2: Alarm output × 2
R4: Alarm output × 4
❷ Power supply
0: 100 - 240 VACᜠ ± 10 % 50 / 60 Hz
1: 24 VDCᜡ ± 10 %
Unit Descriptions
6
7
3
2
1
5
4
No. Part name
Name plate
Function
1
Display part
(red, green, yellow)
-
Run mode: Displays current measured value.
Set mode: Displays parameters.
• C
olor selectable
2
Unit display part (red) -
-
3
Output scale bar
[Transmission output model]
Displays output as % by scale bars.
Alarm output
indicator
[Alarm output model]
Turns ON when the alarm output is on.
4
MODE key
[MODE]
Used to enter monitoring mode and program
mode , move to parameters, save SV and
return to RUN mode.
5
Setting key
[◀], [▼], [▲]
Used to change parameter SV.
6
Digital input
D.IN3
Press the [▼] + [▲] keys for 3 sec, it operates
the set function at digital input key parameter.
7
Input type display
part
01)
-
[Universal input model]
Turns ON when checking or changing the
setting value.
01) In case of thermocouple type, L, N, U, P types are not displayed.
In case of RTD type, RTD is displayed.
Connections
• SOURCE: 100 - 240 VACᜠ 50 / 60 Hz 8 VA
24 VDCᜡ 3 W
■ Universal input (8-pin)
Amp.
OUTPUT
CIRCUIT
3
4
5
6
1
2
7
8
ISOLATION
POWER CIRCUIT
mA
ᜠ
V
mA
mV
2-wire transmitter
01)
-
+
-
+
-
+
-
A
B
b
-
+24V
Analog
TC RTD
+
+
+
+
-
-
-
SOURCE
0 - 20 mA
0 - 10 VDCᜡ
AL
ARM
01) When using 2-wire transmitter, short between no.4 and 5 terminals.
■ Universal input (11-pin)
SOURCE
Amp.
OUTPUT2
CIRCUIT
OUTPUT1
CIRCUIT
5
6
4
3
10
9
2
1
11
7
8
ISOLATION
ISOLATION
POWER CIRCUIT
mA
mA
ᜠ
V
V
mA
mV
2-wire transmitter
01)
Analog
TC RTD
-
+
-
+
-
+
-
A
B
b
-
+24V
+
+
+
+
+
-
-
-
-
ALARM 2
ALARM 1
ALARM 2
ALARM 3
ALARM 4
ALARM 1
0 - 20 mA
0 - 10 VDCᜡ
01) When using 2-wire transmitter, short between no.4 and 6 terminals.
■ Pulse input (8-pin)
SOURCE
Amp.
OUTPUT
CIRCUIT
3
4
5
6
1
2
7
8
ISOLATION
POWER CIRCUIT
mA
ᜠ
V
NPN open
collector
01)
Pulse
Contact
02)
Voltage
+24V
G
In-
In+
OUT
+24V
G
+
+
+
-
-
-
0 - 20 mA
0 - 10 VDCᜡ
AL
ARM
01) Connect external resistance 10 kΩ (≥ 1/2W) to no.3 and 6 terminals for NPN open collector input.
02) Connect external resistance 10 kΩ (≥ 1/2W) to no.3 and 5 terminals for contact input.
■ Pulse input (11-pin)
AL
ARM 2
AL
ARM 1
ALARM 2
ALARM 3
ALARM 4
ALARM 1
0 - 20 mA
0 - 10 VDCᜡ
SOURCE
NPN open
collector
01)
Pulse
Contact
02)
Voltage
+24V
G
In-
In+
OUT
+24V
G
Amp.
OUTPUT2
CIRCUIT
OUTPUT1
CIRCUIT
5
6
4
3
10
9
2
1
11
7
8
ISOLATION
ISOLATION
POWER CIRCUIT
mA
mA
ᜠ
V
V
+
+
+
+
-
-
-
-
01) Connect external resistance 10 kΩ (≥ 1/2W) to no.3 and 5 terminals for NPN open collector input.
02) Connect external resistance 10 kΩ (≥ 1/2W) to no.4 and 5 terminals for contact input.