5 Power module [ARIO-P]
© Copyright Reserved Autonics Co., Ltd.
29
(2)
Slim Remote I/O Power Module
Model
ARIO-P-F1
ARIO-P-F2
ARIO-P-T1
ARIO-P-T2
Input
Voltage
24VDC
ᜡ
±
10% (max. 48W)
ㅡ
Max. current
Max. 2,000mA/CH, 2CH/COM
ㅡ
Output
Voltage
24VDC
ᜡ
±
10% (max. 48W)
24VDC
ᜡ
±
10% (max. 48W)
Max. current
Max. 2,000mA/CH, 6CH/COM
Max. 2,000mA/CH, 8CH/COM
No. of
I/O supply
power
※
1
24V
6
2
8
4
0V
2
6
4
8
Installation method
DIN rail mounting
Insulation resistance
100M
Ω
(at 500VDC
ᜡ
megger)
Dielectric strength
1000VAC
ᜠ
50/60Hz for 1 min
Noise immunity
±
500VDC
ᜡ
the square wave noise (pulse width: 1
㎲
) by the noise simulator
Vibration
0.7mm amplified at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z
direction for 1 hour
Vibration (malfunction)
0.5mm amplified at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z
direction for 10 min.
Shock
300m/s² (approx. 30G) in each X, Y, Z direction for 3 times
Shock (malfunction)
100m/s² (approx. 10G) in each X, Y, Z direction for 3 times
Ambient temperature
-10 to 55
℃
, storage: -25 to 70
℃
(a non-freezing or condensation environment)
Ambient humidity
35 to 85%RH, storage: 35 to 85%RH
(a non-freezing or condensation environment)
Protection structure
IP20 (IEC standards)
Material
Terminal: polyamide6, Body: modified polyphenylene oxide,
Base: polyamide6, poly oxy methylene
Approval
Weight (packaging)
Approx. 75g ( approx. 108g )
※1. For more information on the number of I/O supply power, see “5.4 Wiring diagram.”
※ For connecting the modules, consider power concumption of the sensors and drivers connected
the ARIO power module.