5 Power module [ARIO-P]
28
© Copyright Reserved Autonics Co., Ltd.
5
Power module [ARIO-P]
Be sure to see the “Instruction Manual of ARIO Series” to install the module.
Failure to follow this instruction may result in malfunction and product damage.
5.1
Specifications
(1)
Slim Remote ABUS Power Module
Model
ARIO-P-B
Power
supply
ABUS
(external consumption)
24VDC
ᜡ
, max. 320mA (max. 7.5W, max. 160mA/CH, 2CH/COM)
ABUS
(internal supply)
5VDC
ᜡ
, max. 1,500mA (max. 7.5W)
Installation method
DIN rail mounting
Insulation resistance
100M
Ω
(at 500VDC
ᜡ
megger)
Dielectric strength
1000VAC
ᜠ
50/60Hz for 1 min
Noise immunity
±
500VDC
ᜡ
the square wave noise (pulse width: 1 ㎲) by the noise simulator
Vibration
0.7mm amplified at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction
for 1 hour
Vibration (malfunction)
0.5mm amplified at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction
for 10 min.
Shock
300m/s² (approx. 30G) in each X, Y, Z direction for 3 times.
Shock (malfunction)
100m/s² (approx. 10G) in each X, Y, Z direction for 3 times.
Ambient temperature
-10 to 55
℃
, storage: -25 to 70
℃
(a non-freezing or condensation environment)
Ambient humidity
35 to 85%RH, storage: 35 to 85%RH
(a non-freezing or condensation environment)
Protection structure
IP20 (IEC standards)
Material
Terminal: polyamide6, Body: modified polyphenylene oxide,
Base: polyamide6, poly oxy methylene
Approval
Weight (packaging)
Approx. 75g ( approx. 108g )
※ The ARIO digital module is available to connect up to 8 units, and the ARIO analog and special module are
available to connect up to 4 units.
※ For connecting the modules, consider power concumption of the sensors and drivers connected the ARIO
power module.