Automess 6150AD Скачать руководство пользователя страница 3

Lines Term, Control, and 4.75V are data and power outputs, respectively. They will be discussed in the

next section »Data Outputs«. Lines PL, S/E, and Ext can be regarded as data inputs when using the

6150AD as a ratemeter for external probes. Data inputs will be covered in the appendix »Data Inputs«.

However, this appendix contains confidential information and will be added to this document only on

special request.

2. Data Outputs

2.1 »Term«

The 6150AD calculates a new dose rate value approximately every second and outputs this value as a

string of characters through the Term line. This can be used to read the 6150AD by a computer through a

serial RS232 interface. Output characters are binary and thereby not suitable to be viewed directly on a

serial terminal or printer. The time between two subsequent output strings may vary slightly due to

varying microprocessor load. Nevertheless, counting strings may also be used for time measurement,

since the average time between two strings is exactly equal to 1.049 seconds (2

20

 µs) as derived from the

internal quartz.

Term acts purely as a transmitter, there is no way to feed data into the 6150AD or to request a repeat in

case of transmission errors. Also, there are no handshake signals to control the Term output.

2.1.1 Hardware Characteristics

The Term line is a CMOS gate output with an impedance of several hundred Ohms. Its driving

capability is therefore at least equivalent to RS232 interfaces. Nevertheless, cables should be restricted to

maximum lengths as with RS232 interfaces (15m at 9600Bd, 30m at 4800Bd, etc.). Contrary to RS232

lines the Term output is not short circuit proof and swings between GND and 4.75V because there is no

negative voltage available in the 6150AD.

Term output RS232 output specs RS232 input specs

logical »0«:

+4.75V

+5...+15V

> +3V

logical »1« (marking state): GND

-5...-15V

< -3V

Although the positive Term level of 4.75V does not completely meet the RS232 specification of +5V

minimum, it should be properly recognized by any RS232 device, since any voltage above +3V has to be

recognized as the positive level. The GND level however lies in the undefined range from -3V...+3V.

Fortunately almost all RS232 devices recognize GND level as the negative level. So far we only met one

exception in a many years old IBM serial/parallel adapter using a 75154 input buffer. This input buffer

changes and stores its state only if its input level is outside the -3V...+3V range. If this rare case should

occur, the remedy would be to feed Term through a 1 nF capacitor into the RS232 interface. This

capacitor will differentiate GND to +4.75V and +4.75V to GND transitions to positive and negative

spikes, which will be recognized and stored by the 75154.

06/2003

Technical Manual 6150AD Probe Connector

Page 3 of 14

Daimlerstrasse 27

Telefon  +49(0)6203-9503-00 http://www.automess.de

USt.-ID-Nr. / VAT ID No.

D-68526 Ladenburg Telefax   +49(0)6203-9503-29 eMail: [email protected] DE 144 458 420

Содержание 6150AD

Страница 1: ...Data Inputs 8 3 1 PL and S E Lines 8 3 2 Ext Input 10 3 3 Probe Characteristics 11 Daimlerstrasse 27 Telefon 49 0 6203 9503 00 http www automess de USt ID Nr VAT ID No D 68526 Ladenburg Telefax 49 0...

Страница 2: ...low an will be discussed in more detail later GND Ground potential Note that there is no pin for GND The cable shield serves both as shield and as ground connection The aluminium housing of the 6150AD...

Страница 3: ...ed Ohms Its driving capability is therefore at least equivalent to RS232 interfaces Nevertheless cables should be restricted to maximum lengths as with RS232 interfaces 15m at 9600Bd 30m at 4800Bd etc...

Страница 4: ...xponent 6 block check character The second byte type of detector 6150AD contains Bit 0 5 detector in use 0 probe 6150AD 0 7 probe 6150AD b 15 probe 6150AD 15 17 probe 6150AD 17 18 probe 6150AD 18 19 p...

Страница 5: ...e of detector 6150AD bc sonde mantlo ASC INPUT 1 1 low order mantissa bc bc XOR mantlo manthi ASC INPUT 1 1 high order mantissa bc bc XOR manthi expon ASC INPUT 1 1 exponent bc bc XOR expon IF expon 1...

Страница 6: ...igh indicates that dose rate alarm is off and Control low indicates that dose rate alarm is on This allows triggering of external alarming devices However one has to consider that the Control output c...

Страница 7: ...put battery voltage of 7 0V no load RL 82 5 Ohm Uin V Uout V Iin mA Uout V Iout mA efficiency 5 0 4 782 52 0 4 320 52 4 87 5 5 4 785 55 0 4 651 56 4 87 6 0 4 789 52 5 4 683 56 8 84 7 0 4 795 46 5 4 72...

Отзывы: