background image

4

Tech Support 770-844-4200

www.productivity2000.com

QR Code

Use any QR Code reader application to 

display the module’s product insert.

Important Hot-Swap Information

The Productivity2000 System supports hot-swap! 

Individual modules can be taken offline, removed, and 

replaced while the rest of the system continues con-

trolling your process. Before attempting to use the hot-

swap feature, be sure to read the hot-swap topic in the 

programming software’s help file or our online documen-

tation at AutomationDirect.com for details on how to plan 

your installation for use of this powerful feature.

Align

with slot

2

 rotate

to seated

position

Module Installation

WARNING:

 

Do not apply field power until 

the following steps are completed. See 

hot-swapping procedure for  

exceptions.

WIRE STRIP

LENGTH

WIRE STRIP

LENGTH

Step One: 

Align module 

catch with base slot and 

rotate module into  

connector.

Locked

Unlocked

Step Two: 

Pull top locking tab 

toward module face. Click indi-

cates lock is  

engaged.

Step Three: 

Attach field wiring using the removable 

terminal block or ZIPLink wiring  

system.

Caution: 

If possible, remove field power prior to  

proceeding. If not, then 

EXTREME

 care 

MUST 

be taken 

to prevent damage to the module, or even personal injury 

due to a short circuit from the live terminal block.

Содержание Productivity2000 P2-8AD4DA-2

Страница 1: ...ations 8 General Specifications Operating Temperature 0 to 60 C 32 to 140 F Storage Temperature 20 to 70 C 4 to 158 F Humidity 5 to 95 non condensing Environmental Air No corrosive gases permitted Vib...

Страница 2: ...Output Specifications Output Channels 4 1 common Module Signal Output Range 0 10 VDC 0 5 VDC Output Signal Resolution 16 bit Resolution Value of LSB least significant bit 0 5 V 76 V count 0 10 V 152 V...

Страница 3: ...or DC Voltage Output Circuits V COM 0 5 VDC Load V COM 0 10 VDC Load 24 VDC User Supplied Power 3 Wire Voltage Transmitter V COM 3 Wire Transmitter V1 V2 V3 V4 V5 V6 V8 V7 COM COM 0V CH1 ADC CH2 ADC...

Страница 4: ...your installation for use of this powerful feature 1 Align with slot 2 rotate to seated position Module Installation WARNING Do not apply field power until the following steps are completed See hot s...

Страница 5: ...d output point channel selected and to each Status Bit Item Module Configuration Wiring Options 1 ZIPLink Feed Through Modules and Cables 0 5 m 1 6 ft cable 1 0 m 3 3 ft cable 2 0 m 6 6 ft cable ZL RT...

Страница 6: ...nk Level 7 0 0 0 0 0 0 0 Select the minimum and maximum values of the raw input signal These values will relate to the minimum and maximum scaled values 7 6 5 4 3 2 1 0 1 2 3 4 5 6 7 The Scale Linear...

Страница 7: ...NFO DISPLAY UNITS DECIMAL COUNTS DISPLAY UNITS HEX COUNTS DISPLAY UNITS VOLTS End of Status Menu List MISSING EXTERNAL 24VDC SELFTEST FAIL REPLACE MODULE End of Status Menu List MISSING CONFIG DATA 1I...

Страница 8: ...If you have any questions concerning the installation or operation of this equip ment or if you need additional information please call Technical Support at 770 844 4200 This publication is based on i...

Отзывы: