background image

4

Tech Support 770-844-4200

www.productivity2000.com

QR Code

Use any QR Code reader application to 

display the module’s product insert.

Important Hot-Swap Information

The Productivity2000 System supports hot-swap! 

Individual modules can be taken offline, removed, and 

replaced while the rest of the system continues con-

trolling your process. Before attempting to use the hot-

swap feature, be sure to read the hot-swap topic in the 

programming software’s help file or our online documen-

tation at AutomationDirect.com for details on how to plan 

your installation for use of this powerful feature.

Align

with slot

2

 rotate

to seated

position

Module Installation

WARNING:

 

Do not apply field power until 

the following steps are completed. See 

hot-swapping procedure for  

exceptions.

WIRE STRIP

LENGTH

WIRE STRIP

LENGTH

Step One: 

Align module 

catch with base slot and 

rotate module into  

connector.

Locked

Unlocked

Step Two: 

Pull top locking tab 

toward module face. Click indi-

cates lock is  

engaged.

Step Three: 

Attach field wiring using the removable 

terminal block or 

ZIP

Link wiring  

system.

Caution: 

If possible, remove field power prior to  

proceeding. If not, then 

EXTREME

 care 

MUST 

be taken 

to prevent damage to the module, or even personal injury 

due to a short circuit from the live terminal block.

Содержание Productivity2000 P2-08AD-1

Страница 1: ...the time it was printed At AutomationDirect com we constantly strive to improve our products and services so we reserve the right to make changes to the products and or publications at any time withou...

Страница 2: ...2 201 Safety Input Specifications Input Channel 8 Input Ranges 0 20 mA Signal Resolution 16 bit Resolution Value of LSB least significant bit 0 20 mA 0 305 A per count 1 LSB 1 count Data Range 0 to 6...

Страница 3: ...for current loops 24VDC User Supplied Power User Supplied Transmitter Power AC or DC 032A fuse COM I 3 Wire Current Transmitter 3 Wire Transmitter 24VDC User Supplied Power COM I1 I2 I3 I4 I5 I6 I8 I7...

Страница 4: ...your installation for use of this powerful feature 1 Align with slot 2 rotate to seated position Module Installation WARNING Do not apply field power until the following steps are completed See hot s...

Страница 5: ...Module Configuration Wiring Options 1 ZIPLink Feed Through Modules and Cables 0 5 m 1 6 ft cable 1 0 m 3 3 ft cable 2 0 m 6 6 ft cable ZL RTB20 ZL RTB20 1 ZL P2 CBL18 ZL P2 CBL18 1 ZL P2 CBL18 2 Term...

Страница 6: ...4 5 6 6 5 7 0 0 0 0 0 0 0 Level Transmitter Tank Level 7 0 0 0 0 0 0 0 Select the minimum and maximum values of the raw input signal These values will relate to the minimum and maximum scaled values 7...

Страница 7: ...the cycling Status Info screen This screen will auto cycle with status information Fault Messages Appear in place of data during a fault condition Input current 20mA Input current 0 5 0 6 0 7 0 8 SPAR...

Страница 8: ...evision Date P2 08AD 1 DS 3rd Ed Rev A 2 11 2022 Copyright 2016 AutomationDirect com Incorporated All Rights Reserved Worldwide Diagnostic Status Under Range Error 1 bit per channel Over Range Error 1...

Отзывы: